Possible Charging Programmes; Error Messages - EUFAB 16616 Operating Instructions Manual

Intelligent battery charger 6/12 v 4 a with cable roller
Hide thumbs Also See for 16616:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 7

6.3 POSSIBLE CHARGING PROGRAMMES

6 Volt mode
Charging programme for 6 V batteries, 1.2 Ah to 14 Ah, temperatures above 0°C
Charge current: 2 A maximum
charge voltage: 7.2 V
6 Volt winter mode
Charging programme for 6 V batteries, 1.2 Ah to 14 Ah, temperature below 0°C
Charge current: 2 A maximum
charge voltage: 7.4 V
Motorbike mode
Charging programme for 12 V batteries from 1.2 Ah to 14 Ah, temperatures above 0°C
Charge current: 2 A maximum
charge voltage: 14.3 V
Motorbike winter mode
Charging programme for 12 V batteries from 1.2 Ah to 14 Ah, temperatures below 0°C
Charge current: 2 A maximum
charge voltage: 14.8 V
Car mode
Charging programme for 12 V batteries from 14 Ah to 120 Ah, temperatures above 0°C
Charge current: 4 A maximum
charge voltage: 14.6 V
Car winter mode
Charging programme for 12V batteries from 14 Ah to 120 Ah, temperatures below 0°C
Charge current: 4 A maximum
charge voltage: 14.8 V
Battery maintenance charge mode
This function is automatic and cannot be set directly. As soon as the battery is fully
charged, the battery charger automatically switches to battery trickle charge mode.
This is shown accordingly in the display (Only when removed). Never leave the charger
connected for more than 5 days.

6.4 ERROR MESSAGES

Display of error after faulty connection (wrong poles), short-circuit, connecting a deeply
discharged battery, selection of an incorrect charging programme or overheating.
Error message in 6 V – mode, if a battery is connected with less than 5.5 V ± 0.2 or the
voltage is still lower than 6 V after 4 hours of charging time.
Can also be displayed for 12 V batteries. The charger recognises the deeply discharged
12 V battery as a 6 V