Regulus HSK 350 K P-B Installation And Operation Manual

Thermal store with stainless-steel dhw heat exchanger

Advertisement

Quick Links

www.regulus.eu
EN
Installation and Operation Manual
THERMAL STORE
with stainless-steel DHW heat exchanger
HSK 350 K P-B
HSK 350 K P-B

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the HSK 350 K P-B and is the answer not in the manual?

Questions and answers

Summary of Contents for Regulus HSK 350 K P-B

  • Page 1 Installation and Operation Manual THERMAL STORE with stainless-steel DHW heat exchanger HSK 350 K P-B HSK 350 K P-B...
  • Page 2: Table Of Contents

    1.3 Thermal insulation ..........................1.4 Packaging ............................2 General Information ............................3 Technical Data and Dimensions of HSK 350 K P-B Thermal Store ............4 Operation ............................... 5 Connection of HSK 350 K P-B to a Heating System ................. 6 Installation and Commissioning ........................
  • Page 3: Description

    1 - Description The HSK 350 K P-B Combination Thermal Store with an integrated stainless-steel heat exchanger and a tight separating metal plate is intended for storing heat and heating of domestic hot water. Thanks to the modified construction and the tight separating plate, it is sufficient to use only one zone valve for switching between heating the upper and lower part of the tank.
  • Page 4: Technical Data And Dimensions Of Hsk 350 K P-B Thermal Store

    3 - Technical Data and Dimensions of HSK 350 K P-B Thermal Store Main Features Combination thermal store with integrated stainless-steel heat exchanger and a tight separating metal sheet is intended for heat accumulation and DHW heating. Thanks to its modified...
  • Page 5: Operation

    Dimensions pos. description connection height [mm] Heat sources Incoming from heat source G 1“ F 1390 Return to heat source G 1“ F 1630 Incoming from heat source G 1“ F 1170 Heating system Flow to heating system G 1“ F 1530 Return from heating system G 1“...
  • Page 6: Connection Of Hsk 350 K P-B To A Heating System

    5 - Connection of HSK 350 K P-B to a Heating System │...
  • Page 7: Installation And Commissioning

    6 - Installation and Commissioning Installation must meet valid rules and may be done only by qualified staff. Defects caused by improper installation, use or handling are not covered by warranty. After the tank is installed and connected to an existing heating system, it is recommended to clean the entire heating system using a suitable cleaning agent, e.g.
  • Page 8: Maintenance

    This product is covered by warranty under conditions specified in this Manual and the respective Warranty Certificate. The Warranty Certificate is an integral part of supply of this Thermal Store. v1.0-01/2022 ©2021 We reserve the right to errors, changes and improvements without prior notice. REGULUS spol. s r.o. E-mail: sales@regulus.eu Web: www.regulus.eu...

Table of Contents