Maintenance
REPLACING THE FILTER CONT.
9.
Disconnect and lift the heightening ring (1).
10. Unscrew the cartridge fastening disk (2) and remove it.
11. Lift and extract the cartridges (3) one by one, then replace the old cartridges with new ones.
IMPORTANT! ALL THE MATERIAL TRAPPED BY THE FILTER AND THE FILTER ITSELF MUST
BE DISPOSED OF THROUGH AUTHORIZED CHANNELS IN THE COUNTRY WHERE THE DUST
COLLECTOR IS USED.
12. To replace compressor air filter, access the compressor, unscrew the old filter and replace with
new one.
WARNING! HAND CRUSHING HAZARD!
THE CONTAINER LOCKING OPERATION MUST BE PERFORMED BY ONE PERSON ONLY, WHO MUST GRIP THE HANDLE WITH BOTH
HANDS AND PRESS IT FULLY DOWN.
FILTER REPLACEMENT SCHEDULE
•
406312 Filter Cartridges: Replace every 750 hours
•
402472 HePA Filter: Replace every 750 hours
•
406313 Compressor Air Filter: Check every 30 days. Replace if clogged or every 200 hours
IMPORTANT! ALL WEAR PARTS MUST BE INSPECTED REGULARLY, AS REPLACEMENT TIME VARIES WITH CONDITIONS OF USE.
ALSO CHECK GASKETS REGULARLY FOR AIR LEAKS.
32
1
2
3
406816_RevB