WARNINGS AND GENERAL PRECAUTIONS

• CAUTION! – This manual contains important instructions and warnings for personal safety. Carefully read all parts of this manual. If
in doubt, suspend installation immediately and contact the Nice Technical Assistance.
• CAUTION! – Important instructions: keep this manual in a safe place to enable future product maintenance and disposal pro-
cedures.
• CAUTION! – All installation and connection operations must be performed exclusively by suitably qualified and skilled person-
nel with the unit disconnected from the mains power supply.
• CAUTION! – Any use other than that specified herein or in environmental conditions other than those stated in this manual is
to be considered improper and is strictly forbidden!
• This product may only be used indoors or protected from weather conditions by control unit's housing.
• The product's packaging materials must be disposed of in full compliance with local regulations.
• Do not open the device protection housing as it contains non-serviceable electrical circuits.
• Never apply modifications to any part of the device. Operations other than those specified may only cause malfunctions. The manufacturer
declines all liability for damage caused by makeshift modifications to the product.
• Never place the device near to sources of heat and never expose to naked flames. These actions may damage the product and cause
malfunctions.
• This product is not intended for use by people (including children) with reduced physical, sensory or mental capabilities or who lack experi-
ence and knowledge, unless they have been given supervision or instruction concerning the use of the product by a person responsible for
their safety.
• Make sure that children do not play with the product.
• Check the warnings in the instruction manual for the motor that the product is connected to.
• Handle the product with care, being sure not to crush, knock or drop it in order to avoid damage.
2

PRODUCT DESCRIPTION

The BiDi-Shutter control unit enables the control of a single-phase asynchronous motor, mains pow-
ered, with connection types: Down, Common, Up, used for the automation of awnings, rolling shutters,
Venetian blinds and similar.
The BiDi-Shutter control unit incorporates a radio transceiver that operates at the frequency of 433.92
MHz with rolling code technology to guarantee optimal safety levels.
Each control unit can memorise up to 30 mono or bidirectional transmitters in the series ERA, ERGO,
FLOR, NICEWAY and VERY, which enable the remote control of the unit.
In the 30 transmitters, climatic radio sensors can be memorised, for the automatic control of the control
unit according to weather conditions.
The control unit is equipped with two inputs for controlling the unit by means of external pushbuttons.
Memorisation and programming is possible via the programming pushbutton (figure 1) on the BiDi-Shutter.
The user is guided through the various phases by means of LED signals.
The control unit is equipped with overload, and overheating protection, which will disable the relays to
prevent damage to the circuit.
3

INSTALLATION

The product is subject to hazardous electric voltages
The installation of the BiDi-Shutter and automations must be performed exclusively by technically qualified personnel, in
observance of current legislation and standards, and according to these instructions. All connections must be made with
the system disconnected from the power supply.
The BiDi-Shutter control unit has been especially designed for insertion in a junction box or wall box; its housing does not
feature any protection against water and only basic protection against contact with solid parts. Never place the BiDi-Shutter
in inadequately protected environments.
Never open or perforate the BiDi-Shutter housing, this is subject to hazardous electric voltages!
3.1 - Preliminary checks
The power supply line must be protected by suitable magneto-thermal (compliant with IEC/EN 60898-1 standard, rated up to 16A) and
residual-current circuit breakers.
A disconnection device must be inserted in the power supply line from the electrical mains (the distance between the contacts must be at
least 3mm with an overvoltage category of III) or equivalent system, for example an outlet and relative plug. If the disconnection device for
the power supply is not mounted near the automation, it must have a locking system to prevent unintentional, unauthorized connection.
LED
Programming
pushbutton
1

Advertisement