5
SETTINGS
5.1 - Auto Off
This function allows to automatically turn OFF the connected device when saved time passes from turning ON. By default, the auto OFF func-
tion for both outputs is disabled.
To set auto OFF time or disable the function, proceed as described below.
Table A8 - Setting auto OFF for output 1
01. Press and hold the programming pushbutton (fig. 1).
02. Release the programming pushbutton (fig. 1) when the LED illuminates with green color (3rd position).
03. If you want to disable the auto OFF function, wait 10 seconds, so the programming procedure concludes
automatically.
04. Press key of the transmitter for responsible turning ON the first output or S1 switch to start the timer.
05. Press key of the transmitter for responsible turning OFF the first output or S1 switch to stop the timer.
The maximum time that can be set is 18 hours.
06. The auto OFF time is saved and the programming procedure concludes automatically.
Table A9 - Setting auto OFF for output 2
01. Press and hold the programming pushbutton (fig. 1).
02. Release the programming pushbutton (fig. 1) when the LED illuminates with white color (4th position).
03. If you want to disable the auto OFF function, wait 10 seconds, so the programming procedure concludes
automatically.
04. Press key of the transmitter responsible for turning ON the second output or S2 switch to start the timer.
05. Press key of the transmitter responsible for turning OFF the second output or S2 switch to stop the timer.
The maximum time that can be set is 18 hours.
06. The auto OFF time is saved and the programming procedure concludes automatically.
5.2 - Type of connected switches
The control unit allows to connect momentary or toggle switches to S1 and S2 input. By default, the toggle switch type is set.
To change type of connected switch, proceed as described below.
Table A10 - Setting type of connected switches
01. Press and hold the programming pushbutton (fig. 1).
02. Release the programming pushbutton (fig. 1) when the LED illuminates with violet color (5th position).
03. Press key of the transmitter responsible for turning ON any output to toggle the setting, the LED informs
about current setting:
Fixed violet – momentary switch
Turned off – toggle switch
04. After 10 seconds that the device doesn't receive any signal, the programming procedure concludes auto-
matically.

5.3 - Deleting transmitters

If memorised transmitters and settings need to be deleted, proceed as described below.
Table A11 - Deleting transmitter from memory
01. Press and hold the programming pushbutton (fig. 1).
02. Release the programming pushbutton (fig. 1) when the LED illuminates with yellow color (6th position).
03. Press any key on the acquired transmitter to remove it from memory.
04. LED emits 3 yellow flashes to confirm the correct removal.
05. After 10 seconds that the device doesn't receive any signal, the programming procedure concludes auto-
matically.