5.4 - Factory reset
If the control unit needs to be reset to the factory settings (all transmitters and setting will be deleted), proceed as described below.
Table A12 - Restoring to factory defaults
01. Press and hold the programming pushbutton (fig. 1).
02. Release the programming pushbutton (fig. 1) when the LED illuminates with yellow color (6th position).
03. Press the programming pushbutton (fig. 1).
04. LED emits 5 yellow flashes to confirm the correct reset.
05. The programming procedure concludes automatically.
Afterwards the control unit will initiate the start-up procedure according to table A2.
6

LED SIGNALS

6.1 - Programming menu
When pressing and holding the programming pushbutton on the control unit, the LED will signal consecutive positions of the programming menu.
Table A13 - menu positions when holding the programming pushbutton
Color
1
Red
2
Orange
3
Green
4
White
5
Violet
6
Yellow
6.2 - Other signals
Table A14 - other LED signals
Color
2 red flashes
3 red flashes
3 orange flashes
6 red flashes
6 orange flashes
3 yellow flashes
5 yellow flashes
Description
Memorization in Mode I
Memorization in Mode II
Auto OFF for output 1 settings
Auto OFF for output 2 settings
Switch type settings
Reset
Description
Control unit initialized properly
Transmitter memorized in Mode I
Transmitter memorized in Mode II
Memory for transmitters full (Mode I)
Memory for transmitters full (Mode II)
Transmitter deleted from memory
Control unit restored to factory settings