10.

Technical data

Measuring principle:
Range of application:
Heating:
Supply voltage:
Current consumption:
Housing:
Dimensions:
Included in delivery:
For connection to:
Accessory:
Parameters
Measuring elements:
Measuring ranges:
Accuracy:
Resolution:
Starting value:
Interface:
Protocol:
Weight:
Measured values:
*) [Note: In the event of possible icing and ice formation on the moving sensor element, the
function is limited for the duration of the icing. We off er specially heated sensors for use in
locations with acute icing hazards.]
Quality System certified by DQS according to
DIN EN ISO 9001:2008 Reg. No. 003748 QM08
LAMBRECHT meteo GmbH
Friedländer Weg 65-67
37085 Göttingen
Germany
10
(14567/14577) INDUSTRY Modbus
(14567/14577) INDUSTRY Modbus
Hall Sensor Array, non-contact
temperatures -30...+70 °C heated * • wind speed 0...60 m/s
18 W heating • electronically controlled • The heating within the sensor head prevents blocking
of the moving parts under most climatological conditions.
24 VDC (6...32 VDC)
max. 800 mA at 24 VDC and max. heating • 13 mA at 24 VDC and inactive heating
(Note: The heating can be deactivated via software tool. This allows the current consumption to
be reduced to 8.5 mA at 24 VDC.)
seawater-resistant Aluminium · anodized · IP 55 · shaft-Ø 32 mm · for mounting-bore Ø 30 mm
at max. 10 mm material thickness
see dimensioned drawings
1 sensor (without cable)
Lambrecht meteo data processing systems · power supplies · user specifi c evaluation systems
(not included in delivery)
Id-No. 32.14567.060000 · sensor cable with M12, 4 pin female connector, length: 12 m
(please order separately)
Wind direction
Id-No. 00.14567.110030
wind vane • stably
fi bre-reinforced plastics
0...360°
± 2°
< 0.7 m/s
RS485
Modbus RTU
0.35 kg
instantaneous value · average value · max. value of the average value · min. value of the
average value
Subject to change without notice.
Tel
+49-(0)551-4958-0
Fax
+49-(0)551-4958-312
E-Mail
info@lambrecht.net
Internet www.lambrecht.net
Wind speed
Id-No. 00.14577.110030
3-armed cup anemometer •
fail-safe plastics
0.7...50 m/s
0.5 m/s at 0.7...5 m/s and 2 % FS at 5.02...50 m/s
< 0.02 m/s
< 0.7 m/s
RS485
Modbus RTU
0.25 kg
Please note the loss of warranty and non-liability by unau-
thorised manipulation of the system. You need a written
permission of the LAMBRECHT meteo GmbH for changes
of system components. These activities must be operated
by a qualifi ed technician.
The warranty does not cover:
1. Mechanical damages caused by external impacts (e. g.
icefall, rockfall, vandalism).
2. Impacts or damages caused by over-voltages or elec-
tromagnetic fi elds which are beyond the standards and
specifi cations in the technical data.
3. Damages caused by improper handling, e. g. by wrong
tools, incorrect installation, incorrect electrical installation
(false polarity) etc.
4. Damages which are caused by using the device beyond
the specifi ed operation conditions.