PRO-Modbus · Advantages at a glance
► wear-free, precise data acquisition
► high reliability and longevity
► cup rotor made of seawater-resistant aluminium
► for highest capacity
► simple installation for mast, fl ange and bore
► practical cable plug connection
Descriptions
outstanding protection against electrostatic discharge for
operation in lightning-prone regions
wide range of operating for all-year application in most
climatic zones due to integrated, regulated heating
especially robust due to reinforced axis
very high measuring range of 60 m/s
low starting values of < 0.5 m/s
high resolution of measuring values
very low needs of maintenance
Standards
► EMC acc. to EN 61000-6-2, EN 61000-6-4,
EN 61000-4-2, -3, -4, -5, -6, -11,
Namur NE-21
► VDE 0100
► WMO No. 8
► VDI 3786 part 2
(14523/14524) PRO-Modbus
Content
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
10.1
10.2
10.3
10.4
10.5
10.6
10.7
10.8
11.
Manual
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PRO-Modbus 14523 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Lambrecht PRO-Modbus 14523

  • Page 1: Table Of Contents

    Manual Wind Sensors PRO-Modbus (14523/14524) PRO-Modbus · Advantages at a glance ► wear-free, precise data acquisition ► high reliability and longevity Content ► cup rotor made of seawater-resistant aluminium Warranty ► for highest capacity Initial operation ► simple installation for mast, fl ange and bore Maintenance ►...
  • Page 2: Warranty

    You need a written The bores at the cup rotor and the wind vane are attached in permission of the LAMBRECHT meteo GmbH for changes such a way that they can only be installed in a certain clear of system components.
  • Page 3: Principles Of Installation

    Manual Wind Sensors PRO-Modbus (14523/14524) Principles of installation Please make sure there is no magnetic deviation of the compass. Because the installation take place in a danger- ous height, the assembly personal must follow When the north direction is set up for the wind direction sen- the rules for prevention of accidents.
  • Page 4: Wiring Diagram

    Manual Wind Sensors PRO-Modbus (14523/14524) Wiring diagram (14523/14524) PRO-Modbus Manual...
  • Page 5: Dimensioned Drawings

    Manual Wind Sensors PRO-Modbus (14523/14524) Dimensional drawings Accessory (optional): Mast adapter Id-No. 32.14567.008000 M27x1.5 (14523/14524) PRO-Modbus Manual...
  • Page 6: Modbus-Protocol

    "most signifi cant byte" is sent fi rst. For values that go beyond one register (e.g. 32 bit) this is not clearly specifi ed for the Modbus. In these cases (32 bit or 64 bit) the LAMBRECHT Modbus sensors follow the big-endian number format.
  • Page 7: Measured Value And Parameter Registers

    The registers addresses 30001 to 35000 apply to all LAMBRECHT meteo Modbus sensors, but are only available or valid if the respective sensor supports the corresponding values (e.g. a pure temperature sensor does not provide any wind speed)..
  • Page 8: Mapping Register For Autoconfi Guration

    46001 to 49000 can only be read out as a block! The length of the block or the number of available mapping registers is in holding register 46000. Since the addresses from the range 30001 to 35000 apply to all LAMBRECHT sensors, an address from this range is also representative of a measured value type.
  • Page 9: Mapping Register Pro-Modbus

    Manual Wind Sensors PRO-Modbus (14523/14524) 31501 Global radiation W/m² 2 decimal places LONG 0x04 Big-Endian instantaneous values WORD Registers 31501 + 31502 can (High-WORD) only be read out together (temperature compen- (function code 0x04) sated) 31502 Global radiation 0x04 Big-Endian instantaneous values WORD (Low-WORD)
  • Page 10: Technical Data

    Dimensions: see dimensioned drawings Included in delivery: 1 sensor (without cable) Connectable to: Lambrecht meteo data loggers · power supply units · user specifi c evaluation systems (not included in delivery) Parameters Wind direction (14523) Wind speed (14524) Id-No.

This manual is also suitable for:

Pro-modbus 14524

Table of Contents