Page 1
SIP Tempest PH480/150 Hot Wash Pressure Washer Code: 08953 Instruction manual - Use and Maintenance WARNING. Read the instructions before using the machine.
TRANSLATION OF THE ORIGINAL INSTRUCTIONS Read and keep in mind that indicated in the INSTRUCTION WARNING MANUAL - SAFETY WARNINGS. TECHNICAL CHARACTERISTICS AND SPECIFICATIONS SIP Tempest PH480/150 ELECTRICAL CONNECTIONS Power supply 230 V 1~ 50 Hz Input (kW - HP)
ENI MULTITECH THT corresponding oils: Mobil Mobilfluid 424 Mobil Mobilfluid 426 Petronas Arbor MTF Special 10W-30 Shell Spirax S4 TXM Total Dynatrans MPV Elf Tractelf BF16 Castrol Agri Trans Plus 80W Chevron Textran THD Premium Q8 Roloil Multivariax 35 HP PARTS IDENTIFICATION Refer to figures 1 to 8.
If it trips, follow the instructions below: - turn the main switch (1) to “0” and take the plug out of the mains socket; - press the cleaner gun lever (23) to discharge any remaining pressure; - wait 10 to 15 minutes for the high pressure cleaner to cool down; - check that the requirements for the mains power connections have been followed correctly (see the INSTRUCTIONS MANUAL –...
INSTALLATION – FITTING THE ACCESSORIES • Connect the quick fit connector (27) on the hose (26) to the water outlet connector (5) and secure the ring nut tightly by hand. Step H in Fig. 7. • Screw the connector (25) on the high pressure hose onto the thread of the cleaner gun (17) and tighten it using two 17/22 mm spanners (not supplied).
OPERATION WITH DETERGENT The Manufacturer recommends the use of detergents which are at least 90% biodegradable. Refer to the label on the detergent for instructions on how to use it. • Fill the bottle (34) with the desired detergent. • Regulate the detergent suction capacity in the following way: - disconnect the rod (33) from the lance (32);...
ROUTINE MAINTENANCE Follow the instructions for “STOPPING WORK” and those provided in the table below. MAINTENANCE ACTION SCHEDULE • Check the power cord, the high pressure hose, the connectors, the cleaner E v e r y t i m e t h e gun and the lance pipe.
Page 17
PROBLEM CAUSE SOLUTION Follow the instructions in “ROUTINE The cleaner vibrates a lot The water inlet filter (29) is dirty MAINTENANCE”. and is noisy. The cleaner is taking in air. Check there are no leaks in the suction circuit. Not enough water supply or Check that the tap is fully open and the priming too deep mains water flow rate and priming depth...
Page 18
PROBLEM CAUSE SOLUTION Pressing the main switch Unsuitable electrical system and/ Check the instructions for connecting (1) to position ”I”, the or extension lead up to the mains power supply have motor buzzes, but does been followed correctly (refer to the INSTRUCTIONS MANUAL –...
Leicestershire LE12 9NH England As the manufacturer within the UK, England, Scotland & Wales, declare that the SIP Tempest PH480/150 Hot Wash Pressure Washer Part No. 08953 Conforms to the requirements of the following Directive/s, as indicated. 2006/42/EC Machine Directive...
Page 22
England As the manufacturer within the UK, England, Scotland & Wales, declare that the SIP Tempest PH480/150 Hot Wash Pressure Washer Part No. 08953 Conforms to the requirements of the following Directive/s, as indicated. Supply of Machinery (Safety) Regulations 2008...
Page 23
FOR HELP OR ADVICE ON THIS PRODUCT PLEASE CONTACT YOUR DISTRIBUTOR, OR SIP DIRECTLY ON: TEL: 01509500400 EMAIL: sales@sip-group.com or technical@sip-group.com www.sip-group.com...
Need help?
Do you have a question about the Tempest PH480/150 and is the answer not in the manual?
Questions and answers