Smart Fan Mode Configuration
Smart Fan Mode
FAN Target Temperatur
FAN Tolerance
Smart Fan Mode
[Thermal Cruise Mode] : You can adjust FAN Target Temperatur and FAN Tolerance
manually. If CPU temp is lower than target temp-tolerance, the fan will run at low fan
speed. If CPU temp ishigherer than target temp+tolerance, the fan will run at full fan
speed.
[Manual Mode] : You can set fixed fan speed.
FAN Target Temperature
Input a target temperature between 0 ~ 127°C.
FAN Tolerance
Input a target temperature tolerance.
www.acrosser.com
Aptio Setup Utility - Copyright (C) 2020 American Megatrends, Inc.
Advanced
Version 2.19.1266. Copyright (C) 2020 American Megatrends, Inc.
[Thermal Cruise Mode]
45
2
ANR-DNV3N3 Series
Smart Fan Mode Select
→←: Select Screen
↑↓: Select Item
Enter: Select
+/-: Change Opt.
F1: General Help
F2: Previous Values
F3: Optimized Defaults
F4: Save & Exit
ESC: Exit