(3) Create symbolic links in your top-level directory to allow access to your filesys and images directory
(note: actual directory name may be different depending on your specific release):
# cd /home/z3/z3-dm810x
# ln –s z3-centaurus-dm810x_sdi2_rps-20141016/images images
# ln –s z3-centaurus-dm810x_sdi2_rps-20141016/filesys filesys
(4) Configure u-boot on your board to match your system configuration settings.
(a) Reboot the board with minicom or TeraTerm setup on your PC (see Steps (5)/(6) in Section 6).
(b) Wait for the first stage u-boot to finish and for the second stage u-boot to start.
(c) As soon as the second stage u-boot starts, press the space bar immediately to make it stop in
the u-boot prompt.
(d) The next step is to prepare the environment variable script to match your own environment
settings. Go to the u-boot directory in the release directory and edit the file "u-boot-env-
dm810x-rdk.txt" (here emacs is used – any text editor can be used).
# cd /home/z3/z3-dm810x
# cd z3-centaurus-dm810x_sdi2_rps-20140624
# cd u-boot
# emacs u-boot-env-dm810x-rdk.txt
(e) In the editor, you want to modify the values for nfsserver, serverip, gatewayip, netmask, ipaddr,
tftp_root, and nfs_root – as shown below:
T
The value for tftp_root, when combined with the value of "server_args" in your
/etc/xinetd.d/tftp
___________________________________________________________________________________________
Z3 Technology, LLC ♦ 100 N 8
CONFIDENTIAL

Figure 41 Editing u-boot-env-dm810x-rdk.txt

file (see step (1b)), should point to the images link you set up in step (3).
48
th
ST, STE 250 ♦ Lincoln, NE 68508-1369 USA ♦ +1.402.323.0702
DOC-USR-0055-03
Modify to match the IP address of your Linux PC
Modify to match the IP address of router
Modify to match the netmask of your Linux PC
(should be same as Target netmask)
Modify to match the IP address you want the
target board to be
Modify to match your tftp and nfs configuration
(see below)