Burner Door And Burner Connection - Riello RTT 163 Instructions Manual

Hide thumbs Also See for RTT 163:
Table of Contents

Advertisement

1.24 Burner door and burner connection

When assembling the burner, be careful not to leave any empty
space between the front door and the body of the burner. All the
points of contact should be covered with insulating material to
prevent air leaks.
To make it easier to fix the burner to the door a metal flange is
used. The flange measures 198x198 mm and has a thickness of
10 mm; the burner hole measures 110 mm (3).
The burner door insulation (1) is composed of a special thermal
ceramic that can withstand up to 1250 ºC and is safe for people
to use. Be very careful when transporting the insulating plate.
A ceramic fibre insulating cord is inserted in the door groove. The
cord has the function of preventing leaks between the door and
the front element of the boiler. After cleaning or repair work, put
back the door fixing it solidly to the front element.
In the RTT range of boilers it is possible to choose the opening
side of the door. This feature is an advantage for assembly, repair
operations etc.
The burner door has an inspection window made of tempered
ceramic glass (2).
1
2
3
16