M35(t) / M65(t)
Choose output wire and connectors
For the amplifier output connectors, We recommends using pre-built or professionally wired,
high-quality, and heavy gauge speaker wires. You may use EURO blocks for your output con-
nectors. To prevent the possibility of short-circuits, wrap or otherwise insulate exposed loud-
speaker cable connectors
Using the guidelines below, select the appropriate size wire based on the distance from amplifier
to speaker. The wire sizes apply to the 4-ohm tap.
NOTE : Custom wiring should only be performed by qualified personnel. Class 2 wiring is re-
quired.
CAUTION : Never use shielded cable for output power wiring
6
Distance
Wire Size
Up to 25 ft.
16 AWG
26~40 ft.
14 AWG
41~60 ft.
12AWG
61~100 ft.
10AWG
101ft~150 ft.
8AWG
151~200 ft.
6AWG