Sign In
Upload
Manuals
Brands
Quest Engineering Manuals
Medical Equipment
MPS 3 ND
Quest Engineering MPS 3 ND Manuals
Manuals and User Guides for Quest Engineering MPS 3 ND. We have
4
Quest Engineering MPS 3 ND manuals available for free PDF download: Operation Manual, Troubleshooting Manual
Quest Engineering MPS 3 ND Operation Manual (268 pages)
Smarter Myocardial Protection
Brand:
Quest Engineering
| Category:
Medical Equipment
| Size: 16.97 MB
Table of Contents
Table of Contents
3
Introduction
7
About this Operations Manual
8
Indication for Use
8
Contraindications
8
Symbols Used in this Operations Manual
9
Terminology / Abbreviations
10
System Overview
13
MPS 3 Console
13
MPS 3 Controller
17
MPS 3 Disposables
20
System Specifications and Performance
23
Console Specifications
23
Controller Specifications
25
MPS 3 Disposables Specifications
26
Glossary of Symbols and Labels
27
Console and Controller Symbols and Markings
27
Delivery Set and Optional Accessories Symbols and Markings
28
Warnings and Cautions
31
General Warnings and Precautions
31
Installation and Setup Cautions
34
System Warnings and Cautions
36
Disposable Circuit Priming and Delivery Cautions
38
Priming
39
Cardioplegia Delivery
40
System Cleaning
41
System Alarms
41
System Installation
43
Installation Introduction
43
Unpacking the MPS 3 System
44
Unpacking the MPS 3 Controller
44
Unpacking the MPS 3 Console
45
Unpacking the MPS 3 Disposables
46
System Components
47
System Accessories
49
Installing the MPS 3 System
51
Installing the MPS 3 Console
51
Installing the MPS 3 Hypothermic Reservoir
56
Installing the MPS 3 Controller
62
Connecting a Heater Cooler Unit to the MPS 3 System
70
Priming the Circulation System
73
Installing the Optional Accessories
76
Connecting Medical Air
76
Connecting to the Electronic Data Management System (EDMS)
78
Connecting the Electrocardiogram (ECG) Cable
79
Connecting the External Antegrade and Retrograde Pressure Cables
80
MPS 3 Startup
82
System Power on
82
System Settings
86
Graphical User Interface (GUI) Overview
91
Home Screen Overview
91
Home Screen Views
95
Changing Case Parameters During Delivery
96
Flow Settings
96
Delivery Pressure Settings
98
Time
101
Volume
103
Arrest Agent (K+)
107
Additive
108
Blood : Crystalloid
109
Temperature
111
Function Buttons
112
Vent
113
Ecg
114
ECG Events
115
Hold Volume
117
Graft
117
Menu
119
Protocol
120
Delivery Routes
121
Home
121
Auto Mode and Auto-Start Mode
122
MPS 3 Disposable Installation
124
Installing the MPS 3 Delivery Set
124
Installing the Heat Exchanger
125
Installing the Blood / Crystalloid Cassette
127
Connecting the Delivery Set to the Extracorporeal Circuit
128
Installing and Filling the Arrest Agent Cartridge
130
Installing and Filling the Additive Cartridge
134
Priming and Recirculation
138
Refill Arrest Agent
141
Purging the Arrest Agent Cartridge Line
142
Refill Additive
142
Purging the Additive Cartridge Line
143
Auto Prime for Disabled Arrest and Additive Pumps
143
Replacing the Crystalloid Bag
144
Removing the Delivery Set
145
MPS 3 System Functional Use
147
New Case Setup
147
Defaults
148
Using an Existing Protocol
156
Resuming an Existing Case
157
Using MPS 3 Protocol Manager
157
Interfacing with Menu
160
Settings
160
H2O Circ
160
Device Info
162
File Transfer
163
Case History
165
Additive List
177
Crystalloid List
180
Component List
182
Personnel
183
Error Report
184
Trainer Mode
186
Shut down and Restart
188
Data Transfer
189
Alarm Overview
190
High Priority Alarms
190
Medium Priority Alarms
191
Informational Signals
191
Troubleshooting
192
General Troubleshooting
192
MPS 3 Blood Bypass Tubing
192
Error Code List and Solutions
193
Further Troubleshooting
226
Delivery Line Occlusion/Max Overpressure Alarms
226
Arrest & Additive Alarms
226
Bubble Trap Errors
226
System and Internal Error Alarms (Non-Recoverable Alarms)
226
Delivery Temperature Reads more than 5° above Water Temperature
227
Delivery/Vent Valves Errors
227
Low/No Water Flow in Circulation System
227
Cannot Close the Door
227
Cannot Install Heat Exchanger
227
Inadequate Fill Alarms/Delay in Delivery
229
Battery Not Charged/Charging While Not in Use
229
Air in Delivery Line
229
Circulation System Not Heating
229
Cannot Drain HEX
229
Console or Controller Swap out
230
System Maintenance
235
Cleaning
235
MPS 3 Surface Cleaning and Disinfection
236
Delivery and Vent Valve Cleaning
238
Water Circulation System Cleaning
239
System Controller Cleaning
244
Storage Instructions
245
Preventative Maintenance
245
System Service
245
Service
249
Warranty Service
249
Unscheduled Services
250
Part Numbers and Accessories List
253
Accessories List Skus
253
Power Cords
254
MPS 3 Delivery Sets
255
MPS 3 Disposables Optional Accessories
257
Appendix
261
Electromagnetic Environment Recommendations
261
Electromagnetic Emission
262
Electromagnetic Immunity
262
Recommended Separation Distance
265
MPS® 3 Aortic Root and Coronary Sinus Transducer Interface Cable
266
MPS® 3 Bypass Tubing Instructions for Use
267
Advertisement
Quest Engineering MPS 3 ND Operation Manual (234 pages)
Brand:
Quest Engineering
| Category:
Medical Equipment
| Size: 22.67 MB
Table of Contents
Table of Contents
3
1 Introduction
9
About this Operations Manual
10
Indication for Use
10
Contraindications
10
Symbols Used in this Operations Manual
11
Terminology / Abbreviations
12
2 System Overview
13
MPS 3 ND Console
13
MPS 3 Controller
16
MPS 3 ND Disposables
19
3 System Specifications and Performance
21
Console Specifications
21
Controller Specifications
23
MPS 3 ND Disposables Specifications
24
Glossary of Symbols and Labels
25
Console and Controller Symbols and Markings
25
Delivery Set and Optional Accessories Symbols and Markings
27
4 Warnings and Cautions
29
General Warnings and Precautions
29
Installation and Setup Cautions
31
System Warnings and Cautions
33
Disposable Circuit Priming and Delivery Cautions
35
Priming
36
Cardioplegia Delivery
37
System Cleaning
38
System Alarms
38
5 System Installation
39
Installation Introduction
39
Unpacking the MPS 3 ND System
40
Unpacking the MPS 3 Controller
40
Unpacking the MPS 3 ND Console
41
Unpacking the MPS 3 ND Disposables
41
System Components
42
System Accessories
43
Installing the MPS 3 ND System
45
Installing the MPS 3 ND Console
45
Installing the MPS 3 Controller
51
Connecting a Heater-Cooler Unit to the MPS 3 ND System
58
Priming the Water Circuit
61
Installing the Optional Accessories
62
Connecting Medical Air
62
Connecting to the Electronic Data Management System (EDMS)
64
Connecting the Electrocardiogram (ECG) Cable
65
Connecting the External Antegrade and Retrograde Pressure Cables
66
6 MPS 3 ND Startup
69
System Power on
69
System Settings
73
7 Graphical User Interface (GUI) Overview
77
Home Screen Overview
77
Home Screen Views
81
Changing Case Parameters During Delivery
83
Flow Settings
83
Delivery Pressure Settings
84
Time
87
Volume
89
Arrest Agent (K+)
93
Additive
94
Blood : Crystalloid
95
Temperature
97
Function Buttons
98
Vent
99
Ecg
100
ECG Events
101
Hold Volume
103
Graft
104
Menu
105
Protocol
106
Delivery Routes
107
Home
107
Auto Mode and Auto-Start Mode
108
8 MPS 3 ND Disposable Installation
109
Installing the MPS 3 ND Delivery Set
109
Installing the Heat Exchanger
110
Installing the Blood / Crystalloid Cassette
112
Connecting the Delivery Set to the Extracorporeal Circuit
114
Installing and Filling the Arrest Agent Cartridge
115
Installing and Filling the Additive Cartridge
119
Priming and Recirculation
122
Refill Arrest Agent
126
Purging the Arrest Agent Cartridge Line
127
Refill Additive
127
Purging the Additive Cartridge Line
128
Auto Prime for Disabled Arrest and Additive Pumps
128
Replacing the Crystalloid Bag
129
Removing the Delivery Set
130
9 MPS 3 ND System Functional Use
131
New Case Setup
131
Defaults
132
Using an Existing Protocol
140
Resuming an Existing Case
141
Using MPS 3 Protocol Manager
141
Interfacing with Menu
144
Settings
144
H2O Circ
144
Device Info
145
File Transfer
145
Case History
148
Additive List
159
Crystalloid List
161
Component List
162
Personnel
162
Error Report
164
Trainer Mode
165
Shut down and Restart
167
Data Transfer
168
10 Alarm Overview
169
High Priority Alarms
169
Medium Priority Alarms
170
Informational Tones
171
11 Troubleshooting
173
General Troubleshooting
173
MPS 3 Blood Bypass Tubing
173
Alarm Code List and Solutions
174
Further Troubleshooting
205
Delivery Line Occlusion/Max Overpressure Alarms
205
Arrest & Additive Alarms
205
Bubble Trap Errors
205
System and Internal Error Alarms (Non-Recoverable Alarms)
206
Delivery Temperature Reads more than 5° above Water Temperature
206
Delivery/Vent Valves Errors
206
Low/No Water Flow in Water Circuit
206
Cannot Close the Door
206
Cannot Install Heat Exchanger
206
Inadequate Fill Alarms/Delay in Delivery
207
Battery Not Charged/Charging While Not in Use
207
Air in Delivery Line
207
Console or Controller Swap out
208
12 System Maintenance
209
Cleaning
209
MPS 3 ND Surface Cleaning and Disinfection
210
Delivery and Vent Valve Cleaning
212
Water Circuit Care
213
System Controller Cleaning
213
Storage Instructions
213
Preventative Maintenance
214
System Service
215
13 Service
219
Warranty Service
219
Unscheduled Services
220
14 Part Numbers and Accessories List
221
Accessories List SKU
221
MPS 3 ND Delivery Sets
222
MPS 3 ND Disposables Optional Accessories
223
15 Appendix
225
Electromagnetic Environment Recommendations
225
Electromagnetic Emission
226
Electromagnetic Immunity
227
Recommended Separation Distance
231
MPS 3 Aortic Root and Coronary Sinus Transducer Interface Cable
233
MPS ® 3 Bypass Tubing Instructions for Use
234
Quest Engineering MPS 3 ND Troubleshooting Manual (60 pages)
Brand:
Quest Engineering
| Category:
Medical Equipment
| Size: 2.46 MB
Table of Contents
Table of Contents
3
Introduction
5
System Overview
7
Alarm Overview
15
High Priority Alarms
15
Medium Priority Alarms
16
Informational Signals
16
Troubleshooting
17
General Troubleshooting
17
MPS® 3 Blood Bypass Tubing
18
Alarm Code List and Solutions
20
Further Troubleshooting
57
Max Overpressure Alarms
57
Arrest & Additive Alarms
57
Bubble Trap Errors
57
System and Internal Error Alarms (Non-Recoverable Alarms)
58
Delivery Temperature Reads more than 5º above Water Temperature
58
Delivery/Vent Valve Errors
58
Low/No Water Flow in Water Circuit
58
Cannot Close Door
58
Cannot Install Heat Exchanger
59
Inadequate Fill Alarms/Delay in Delivery
59
Battery Not Charged/Charging While Not in Use
59
Air in the Delivery Line
59
Console or Controller Change out
60
Advertisement
Quest Engineering MPS 3 ND Troubleshooting Manual (56 pages)
Brand:
Quest Engineering
| Category:
Medical Equipment
| Size: 1.46 MB
Table of Contents
Table of Contents
3
Introduction
5
System Overview
7
Alarm Overview
13
High Priority Alarms
13
Medium Priority Alarms
14
Informational Tones
15
Troubleshooting
17
General Troubleshooting
17
MPS ® 3 Blood Bypass Tubing
18
Alarm Code List and Solutions
20
Further Troubleshooting
53
Max Overpressure Alarms
53
Arrest & Additive Alarms
53
Bubble Trap Errors
53
System and Internal Error Alarms (Non-Recoverable Alarms)
54
Delivery Temperature Reads more than 5º above Water Temperature
54
Delivery/Vent Valve Errors
54
Low/No Water Flow in Water Circuit
54
Cannot Close Door
54
Cannot Install Heat Exchanger
55
Inadequate Fill Alarms/Delay in Delivery
55
Battery Not Charged/Charging While Not in Use
55
Air in the Delivery Line
55
Console or Controller Change out
56
Advertisement
Related Products
Quest Engineering MPS 3
Quest Engineering TELSEC MP2
Quest Engineering M6
Quest Engineering M3 Mk2
Quest Engineering M35
Quest Engineering M65
Quest Engineering M35t
Quest Engineering M65t
Quest Engineering M120bt
Quest Engineering M Series
Quest Engineering Categories
Amplifier
Dehumidifier
Speakers
Medical Equipment
Metal Detector
More Quest Engineering Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL