3.6.7.5
Display of the operating state
The operating state and functioning of the device are indicated by five LEDs:
● POWER
● CHANNEL 1
● CHANNEL 2
● CH 1 (t)
● CH 2 (t)
Operating states of 3TK2827/28
= off
= on
LED
POWER
Ch 1
Ch1 = Channel 1
Ch2 = Channel 2
FK1 = enabling circuit 1, instantaneous
FK2 = enabling circuit 2, instantaneous
FK1 (t) = enabling circuit 1, time-delayed
FK2 (t) = enabling circuit 2, time-delayed
3TK28 safety relays
Manual, 07/2016, NEB926157502000/RS-AB/003
Ch 2
Ch 1 (t) Ch 2 (t)
Description of the individual safety relays
3.6 3TK28 safety relays with relay enabling circuits
Line
EMERGENCY
supply
STOP
On
Not pressed
Pressed, delay
time running
Pressed
Not pressed
Relay welded
•
Motor contactor welded
•
Fault in electronics
•
Short-circuit in ON circuit
•
Cross-circuit in EMERGENCY STOP circuit (minimum fault
current I
= 0.5 A;
Kmin
PTC fuse responds) or supply voltage missing
Operation
ON
Enabling circuit
Pressed
Closed
Not pressed
FK1 & FK2 open,
FK1 (t) & FK2 (t)
closed
Not pressed
Open
Not pressed
Open
Fault
Open