Figures 3.6, 3.7 and 3.8 show how to connect the pitch converter board FLX-144NSD for 144-pin
0.5-mm-pitch package, how to connect the pitch converter board FLX-144NSE for 144-pin 0.4-mm-
pitch package and how to connect the pitch converter board FLX-120NSE for 120-pin 0.4-mm-pitch
package, respectively.
Figure 3.6 Connecting the pitch converter board FLX-144NSD for 144-pin 0.5-mm-pitch LQFP
Note on Connecting the Target System:
• Take care not to mount the pitch converter board in a wrong direction.
(1) Mount the NQPACK144SD included in the FLX-
144NSD (separately available) to the target system.
(2) Connect the YQPACK144SD included in the FLX-
144NSD to the NQPACK144SD. Secure the
YQPACK144SD using the YQ-GUIDE's.
(3) Connect the FLX-144NSD to the M30220TF-PRB.
(4) Connect the FLX-144NSD to the YQPACK144SD.
CAUTION
( 23 / 54 )