Electric Central Heating Flow Boiler
EKP.LN2M
Assembly and operating instructions

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the EKP.LN2M and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Kospel EKP.LN2M

  • Page 1 Electric Central Heating Flow Boiler EKP.LN2M Assembly and operating instructions...
  • Page 2 This appliance can be used by children aged from 3 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved.
  • Page 3: Safety Instructions

    Safety instructions Read and strictly follow the installation and operating instructions to ensure a long life and reliable boiler operation. An efficient electrical installation which has been completed in accordance with the binding norms of electric installation. A wet central heating system equipped with appropriate expansion vessel made according to binding norms of hydraulic installation- closed system.
  • Page 4 Plastic pipes at the inlet and outlet may be used to connect the water heater, and in the case of the outlet pipes, their strength shall be at least 20 bar at 70°C. Make sure that the heater is not emptied of water, which may occur if there is no water in the supply network.
  • Page 5: Assembly And Installation

    Assembly and installation Hang the boiler up in a vertical 406mm position on fixing screws with the inlet and outlet pipes to the bottom, maintaining clearances from the walls and the ceiling. Connect the boiler to the central heating system equipped with a cut- 150mm 260mm off valves.
  • Page 6 Boiler connection to the CH system control control valve valve cold water cold water hot water hot water ZK - cut-off valve ZT - thermostatic valve ZP - passage valve F - magnetic filter G - radiator RT - room temperature thermostat Tos - outside temp.
  • Page 7 Connection of external appliances RP RP PUMP PUMP ext. ext. room thermostat Room thermostat (RT entry) – when the voltage free contact gets opened the boiler will stop heating. The entry is responsible for boiler's control depending on the room temperature (room thermostat connection details –...
  • Page 8 DHW system venting Shut off the heater's electric supply. Turn the flow on (turn the hot water tap on) in order to vent the water installation (for about 15-30 seconds), until the flow of water becomes constant and even. Switch on the electric supply. Start up - CH system Check if required pressure has been reached within the installation (see section "Technical Data").
  • Page 9: Advanced Settings

    Advanced settings For advanced settings switch the control panel to stand-by mode (press and hold button for approximately 3 seconds) then press and hold , button, and for a short period of time press and let go. To select parameter press to change the value press heating curve coefficient, weather compensation switch off: •...
  • Page 10 pump's working mode: • PA - automatic, • PC - constant. pump's efficiency [E]: • E3.0 - 3.0m, • E4.0 - 4.0m, • E5.0 - 5.0m, • E7.0 - 7.0m, • E7.5 - 7,5m. pump pressure mode [PPn]: • constant pressure difference (pressure indicator- on), •...
  • Page 11: Control Panel

    Control panel A - pressure [bar] B - flow [l/min] C - power [kW] D - temperature [°C] E - digital display F - indicator of room termostat and heating activity (for central heating) G - indicator of pump and flow activity H - indicator of weather compensation controller I - inlet temperature indicator J - outlet temperature indicator...
  • Page 12 Stand-by mode In stand-by mode the pump is activated everyday for 2 min, which prevents seizure of the pump. To switch between stand-by mode and summer/winter mode press and hold the power button for 3 seconds. Stand-by is indicated by briefly showing on the display followed by the display turning blank.
  • Page 13 Summer mode Summer mode is active when the icon is active and the icon is inactive. In summer mode (main view) the control panel displays icons describing the current device operation. Digital display shows the output temperature of domestic water, if heating conditions exist.
  • Page 14: Icons And Indicators

    Icons and indicators Indicator Status Details room thermostat allows the boiler to heat required temperature has been reached (boiler doesn’t heat) flickering master appliance doesn’t allow to heat (MA entry) pump is active, a proper flow rate of medium has been reached lack of flow or insufficient flow rate of medium flickering...
  • Page 15: Fault Finding

    Fault finding Symptom Reason Action check parameters of power network and fuses Indicators on control panel lack of device's power supply. are off contact authorised service shift the controller to the pressure view, increase pressure within the insufficient pressure (below 0,5 bar) installation to required level (1.5bar A indicator flickers Cold)
  • Page 16: Technical Data

    Technical data EKP.LN2M Rated power 13.2 Rated voltage 230V~ 400V 3N~ Rated current 52.2 57.5 3x26.3 3x34.6 Min. connecting wires section 3x16 Max. connecting wires section 3 x 25 5 x 25 The maximum allowed network Ω 0.24 0.22 0.27 0.13...
  • Page 17 EKP.LN2M Rated power 10.1 12.1 16.3 21.7 Rated voltage 220V~ 380V 3N~ Rated current 54.5 60.0 3x27.3 3x36.5 Min. connecting wires section 3x16 Max. connecting wires section 3 x 25 5 x 25 The maximum allowed network Ω 0.24 0.22 0.27...
  • Page 18 CH boiler Max. pressure 0,3 (3 bar) Min. pressure 0,05 (0,5 bar) Outlet temperature °C 20 ÷ 85 Max. temperature °C Dimensions 690 x 451 x 258 (height x width x depth) Weight Boiler's connections ø 22mm Expansion vessel Safety class IP 21...
  • Page 19 Used product can’t be treated as general communal waste. Disassembled appliance has to be delivered to the collection point of electrical and electronic equipment for recycling. Appropriate utilisation of used product prevents potential negative environmental influences that may occur as a result of inappropriate handling of waste.
  • Page 20 KOSPEL Sp. z o.o. 75-136 Koszalin, ul. Olchowa 1, Poland tel. +48 94 31 70 565 serwis@kospel.pl www.kospel.pl Made in Poland...

Table of Contents