Sagi KP12G1M Use And Installation Manual page 90

Upright refrigerated display units
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 73
HIGH AND LOW TEMPERATURE ALARMS MEMORIZED
In the event that another alarm event were to occur, for high or low temperature, if the
information relative to the preceding anomaly hasn't been visualised by the operator, this
latter will be overwritten by the more recent data.
If the high temperature alarm is on, the compressor keeps working; if the low temperature
alarm is on, the compressor stops.
! If the card is set to the stand-by mode, the min. / max. temperature memorized and
any alarms will not be saved.
BLACKOUT ALARM
HIGH CONDENSATION TEMPERATURE ALARM
If the condensation temperature is too high, due to dirty condenser, the label [HtC] and the
room temperature alternate on the display.
The buzzer sounds.
The buzzer can be turned off by pressing the key
The visual warning signal stays on until the condensation tempertaure returns to normal
range.
HIGH PRESSURE ALARM
If the refrigerating appliance pressure is above the specified limit, the label [HP] and the
room temperature alternate on the display.
The defrost led blinking at high frequency indicates high or low
temperature alarm.
Pushing the enter button the type of alarm recorded will be
visualised on the flashing display.
Pushing the enter button the critical temperature recorded will be
visualised on the flashing display.
Pushing the enter button the time duration of alarm event,
expressed in minutes, will be visualised on the flashing display.
Pushing the enter button the operation of the defrost LED will be
reset to its normal state.
The display shows [rES] after the abnormal event.
The defrost led blinking at high frequency indicates a blackout
Pushing the enter button the [bLO] label will be visualised on the
display.
Pushing the enter button the maximum temperature recorded in
the chamber will be visualised on the display.