Sagi KP12G1M Use And Installation Manual page 81

Upright refrigerated display units
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 73
The units have been declared to be in the 4 (T = 30° C U.R. = 55%) climate class.
Climate
class
temperature
3
4
5
7
Remove protective film from product.
This may cause unpleasant static electricity discharge which, however, is
not dangerous. The inconvenience is reduced or prevented by
continuously holding the refrigerator with one hand or grounding the
package.
The electrical mains cables must be correctly sized and selected based on the installation
conditions.
The models have 3m of single phase cable (3G 1,5mm²) with a SCHUKO
type plug.
Check and verify that the line voltage corresponds to that found on the
technical specifications plaque on the unit. The manufacturer recommends
that a sole use circuit be dedicated for the unit.
WARNING: An omnipolar switch is to be installed before the appliance, in
compliance with the current regulations applied in the country where the
appliance is installed.
Also recommended to install a differential switch.
Then insert the plug into the current tap.
Now the installation has come to end.
GENERAL CLEANING AND MAINTENANCE
For regular and constant service of the unit it would be well to regularly carry out general
cleaning and maintenance operations.
WARNING: The cleaning and maintenance of the refrigerating engine and the compressor
area needs the intervention of a skilled technician, therefore it cannot be done by other
persons.
Room
Relative humidity
+25°C
+30°C
+40°C
+35°C
60%
55%
40%
75%
11