Sagi KP12G1M Use And Installation Manual page 87

Upright refrigerated display units
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 73
Push the enter to confirm the choice and activate the function.
After 30 seconds if not confirmed the program exits the function.
To unlock the keyboard it is necessary to press the
simultaneously for more than 3 seconds: in confirmation of the operation
on the display the message [UnL] appears, flashing, accompanied by 3
short beeps of the buzzer.
Immediately afterwards, the display returns to the indication of the
temperature in the cell.
With the keyboard locked, pressing any button, the instrument emits a
long beep indicating the [Loc] message on the display.
PROBE READING MANUAL PRINTING: Coupled with the TSP print terminal
Push the up and down buttons simultaneously and hold down for more
than 3 seconds.
The label [Loc] is visualised.
Use the up and down buttons to visualise the [Prt] function.
Push the enter to confirm the choice and activate the function.
After 30 seconds, if not confirmed, the program exits the function.
Information accessible to qualified staff only.
Push the up and down buttons simultaneously and hold down for more
than 3 seconds.
The label [Loc] is visualised.
Use the up and down keys to display the function [PAr].
Press the enter key to enter the parameter configuration mode.
After 30 seconds if not confirmed the program exits the function.
Enter the password to gain access.
The display shows the password setting mode [00]
Use the up and down keys to select the password "65"
Press the enter key to confirm your selection.
If the password is correct, the display shows the first parameter in the
configuration list.
PARAMETER CONFIGUTATION