The air condenser should be kept clean to ensure the device performance and efficiency,
as air should circulate inside the device without barrier.
WARNING: The condenser should therefore be cleaned every 30 days or as needed
A dirty Condenser can result in NON-WARRANTEED part & Compressor Failures, Product
Loss.
Before to begin with the operations proceed as following:
- set the general cut-out in OFF position;
- remove the plug from the socket and wait till the complete entfrosting of the unit.
To access the condenser it is necessary to remove the front dashboard:
1. Remove the lower instrument panel, grasping it on the side, freeing it from the four
retaining bolts.
2. Remove the cable from the panel control board.
3. use a vacuum cleaner, brush or non-metallic brush to carefully clean the condenser.
Accurately clean the condenser in the refrigerating unit and the inner evaporator with
either a vacuum cleaner, a bristle brush or a non-wire brush after removing the
protections.
Perform lubrication to ensure regular operation of the "soft motion" flapdoor opening
system.
ATTENTION: the operations described must be carried out by specialised technical
personnel.
- Remove the two front guards, unscrewing the fixing screws on the internal sides of the
same; to complete this operation the doors must be opened one at a time.
- Remove any traces of dust and/or dirt.
12