Sagi KP12G1M Use And Installation Manual page 89

Upright refrigerated display units
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 73
The appliance keeps operating in storing according to the values given to parameters C5
and C6.
The inner fan keeps operating according to the value given to "F3"
Condenser probe error
If the condenser probe is broken or the relevant connection interrupted, the display shows
the label [E2].
The condenser fan keeps operating according to the value given to parameter "F8".
If the three probes are broken or disconnected, E0, E1, and E2 alternate on the display.
UNIT WITH BROKEN SENSOR PROBES DURING DEFROST
Room probe error
In the event that the chamber sensor probe is broken or the respective connection has
been interrupted during the defrost phase the function will be completed normally.
The string set with the parameter "d6" and the label [E0] will be visualised alternatively on
the display.
Condenser probe error
If the condenser probe is broken or the relevant connection interrupted, the display shows
the label [E2].
The condenser fan keeps operating according to the value given to parameter "F8".
If the three probes are broken or disconnected, E0, E1, and E2 alternate on the display.
HIGH TEMPERATURE ALARM
If the room temperature exceeds the setpoint, the label [AH] and the
temperature reached alternate on the display.
Press up to display the duration of the event causing the alarm.
The buzzer may be silenced by pressing the button
The visual alarm signal stays on until the temperature returns within the normal range.
LOW TEMPERATURE ALARM
The buzzer may be silenced by pressing the button
The visual alarm signal stays on until the temperature returns within the normal range.
If the room temperature is below the setpoint, the label [AL] and
the temperature reached alternate on the display. The buzzer
sounds.
Press down to display the duration of the event causing the
alarm.
19

Advertisement

Table of Contents
loading

This manual is also suitable for:

Kp12g2mP12g1mP12g2m

Table of Contents