Adjusting the minimum setting for LPG
Burner and nozzle specifications tables
1 ULPG 2.75 kPa
Nominal gas consumption (MJ/h)
Injector (1/100 mm)
2 NG 1.0 kPA
Nominal gas consumption (MJ/h)
Injector (1/100 mm)

5.4 Positioning

Heavy appliance
Crushing hazard
• Position the appliance into the cabinet
cut-out with the help of a second person.
• WARNING: In order to prevent
accidental tipping of the appliance, the
stabilising means must be installed.
Pressure on the open door
Risk of damage to the appliance
• Never use the oven door to lever the
appliance into place when fitting.
• Avoid exerting too much pressure on the
door when open.
38
Installation
Tighten the screw located at the side of the
cock rod clockwise all the way.
AUX
SR
3.9
6.3
0.54
0.68
AUX
SR
3.9
7.5
0.90
1.20
• Veneers, adhesives or plastic coatings
on adjacent furniture should be
temperature-resistant (not less than
90°C).
General information
This appliance may be installed next to
walls, one of which must be higher than the
worktop, at a minimum distance of 150 mm
from the side of the appliance, as shown in
figures A and C relative to the installation
classes.
Following adjustment to a gas
other than the one originally set in
the factory, replace the gas setting
label on the appliance with the
one corresponding to the new gas.
The label is inserted inside the
nozzle pack (where present).
FB
R
6.8
10.8
0.72
0.88
FB
R
7.8
12.0
1.26
1.55
Heat production during appliance
operation
Risk of fire
UR2
15.0
1.05
UR2
15.0
1.75