ON Series m
Please read and save these instructions. This manual
contains important instructions for the ON Series m
UPS
UPS family. Follow these instructions during the
unpacking, installation and maintenance of the
Uninterruptible Power Supply (UPS) and batteries.
If you have a problem with the UPS, please refer to
this manual before calling Technical Services. The
Troubleshooting Section starting on page 16
addresses most UPS-related issues.
Introduction
Thank you for selecting this uninterruptible power
supply (UPS). ONEAC's ON Series offers the most
reliable protection from the harmful effects of
electrical line disturbances for your computing and
communications equipment. ONEAC's ISO 9001
certification represents our commitment to building
world-class products. We take pride in every unit that
leaves our manufacturing facility
Technical
ONEAC
contact ONEAC Technical Services:
Support
NOTE: All calls received before 7 a.m. or after 7p.m.
Central Standard Time are forwarded to a cell
phone. An ONEAC Technical Support Representative
will return your call within one half hour between 5
p.m. and 10 p.m. Central Standard Time. Except for
emergencies, calls received between 10 p.m. and 7
a.m. will be returned during normal business hours.
Please check with ONEAC Technical Services
before attempting to repair or return any ONEAC
product. If an ONEAC unit needs repair or
replacement, ONEAC Technical Services issues a
Return Material Authorization (RMA) number along
with instructions on how to return the unit.
ON Series m UPS User Instruction Manual
All manuals and user guides at all-guides.com
ON Series m UPS
®
offers 24-hour technical support. To
• North America: (800) 327-8801 (opt. 3) or
(847) 816-6000 (opt. 3)
• Europe: +44 (0) 2380 610311
• email: ts@oneac.com.
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ON Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for ONEAC ON Series

  • Page 1 ON Series m UPS ON Series m Please read and save these instructions. This manual contains important instructions for the ON Series m UPS family. Follow these instructions during the unpacking, installation and maintenance of the Uninterruptible Power Supply (UPS) and batteries.
  • Page 2 Do not remove the cover. All repairs should be done by qualified service personnel. Voltages inside the UPS may be lethal. Internal components are powered even when the power switch is in the “OFF” ON Series m UPS User Instruction Manual...
  • Page 3 Features The ON Series m UPS models are listed for UL2601-1 and CSA-C22.2 compliance and carry the CE Mark for testing to the EN60601-1 standard for Medical Electrical equipment.
  • Page 4: Unpacking And Inspection

    CAUTION: Do not cover or install the UPS in a confined or enclosed space. Changing Frequency This ON Series m UPS was designed to operate at frequencies of either 50 Hz or 60 Hz. The table below shows the frequency settings as shipped from the factory.
  • Page 5: Connecting External Battery Enclosure(S)

    (2) screws removed in step 2. Return the desktop UPS to the upright position. Connecting External For additional runtime, some ON Series m UPSs can Battery Enclosure(s) use extra batteries housed in a separate enclosure. Use only ONEAC model ONMXBC-217. The UPS power module and battery enclosure(s) are shipped separately.
  • Page 6 Repeat step 2 to connect additional external battery enclosures. fig. 2: ON Series UPS and External Battery Connections Connections Before beginning, shut down and unplug the equipment to be protected. DO NOT make any...
  • Page 7 Connector IEC 320 (F) Output Connectors External Battery Input Connector ONm 300 ONm 600 fig. 4: ON Series m UPS I and J Models Back Panel IEC 320 (M) Input Connector IEC 320 (F) Output Connectors External Battery Input Connector...
  • Page 8 Power be Protected be Protected be Protected Input power cord disconnected from protected device IEC320 M/F power cord, (1) provided fig. 6: Connecting Load(s) to UPS and Connecting UPS to AC Power Source ON Series m UPS User Instruction Manual...
  • Page 9: Power Switch

    Indicator Lights Power Switch fig. 7: ON Series m UPS Front Panel Self Test The UPS checks vital functions when it is first plugged in and indicates the status with the three LEDs on the front panel. A green LED indicates normal AC output.
  • Page 10: Low Battery

    UPS is on inverter. If blinking, it indicates the battery is charging when on line or low battery if running on inverter. RED - When the red LED is on solid, it indicates there is a problem with the battery charger or ON Series m UPS User Instruction Manual...
  • Page 11 A positive signal (3 to 24V DC) on pin 20 with respect to pin 21 shuts down the UPS. A signal at or below ground allows the UPS to keep running. ON Series m UPS User Instruction Manual...
  • Page 12: Replacing Battery(Ies)

    Shutdown (to UPS) Shutdown (to UPS) Interface Port ONm 300 ONm 600 fig. 8: ON Series m UPS Rear Panel Replacing NOTE: To obtain new battery(ies), contact ONEAC Technical Services at (847) 816-6000, or toll free at Battery(ies) (800)-327-8801, ext. 3. In Europe, dial +44 (0) 1235 534721.
  • Page 13 8. Close the battery access door and secure with the (2) screws removed in step 2. Return the desktop UPS to the upright position. 9. Dispose of the old battery pack according to ON Series m UPS User Instruction Manual...
  • Page 14 Battery Wires Battery fig. 9: ON Series m UPS Battery Replacement Replacing External For additional runtime, some ON Series m UPSs can Battery Enclosure(s) use extra batteries housed in a separate enclosure. The UPS power module and battery enclosure(s) are shipped separately.
  • Page 15: Battery Disposal

    3 or in Europe at +44 (0) 1235 534721 for an RMA number. Mark the RMA number on the packing slip and shipping carton. 2. Phone ONEAC Corporation for the number of a local battery collection site (US only). 3. Make arrangements with a local auto shop that collects automotive batteries for reprocessing.
  • Page 16 You can access these numbers on the back panel of the unit on a label located near the receptacles. Always check with ONEAC Technical Services before attempting to repair or return any ONEAC product. ON Series m UPS User Instruction Manual...
  • Page 17: Troubleshooting

    All manuals and user guides at all-guides.com Troubleshooting If you have questions or problems regarding you ON Series m UPS, refer to the troubleshooting table below. Table 4. Troubleshooting Problem Possible Cause Solution Front Panel Switch not Switch the Power Switch to (I) “ON”.
  • Page 18: Appendix A: Warranty

    ONEAC’s option, any defective component, circuit board, or module contained within the product only when it is returned with an ONEAC Return Material Authorization (RMA) number to ONEAC or to an ONEAC-designated repair facility. In all cases, the...
  • Page 19: Limitations Of Warranty

    Except as set forth herein and except as to title, there are no warranties, express or implied, or any affirmations of fact or promises by ONEAC for the products, their merchantability, or fitness for any particular purpose. In no event shall ONEAC be liable for lost profits, goodwill or any other special or...
  • Page 20: Appendix B: Typical Runtime

    250 VA 0:07 0:20 300 VA 0:05. 0:15 NOTE: Due to application specific conditions, your actual run time may be different. Table 6. ON Series m 600 VA Extendable Runtimes Typical Runtime ONm600X Plus1 Plus2 Plus 3 Plus 4 Plus 5...
  • Page 21 (TRUE condition causes “short” to RETURN signal (pin 11)) inverter shut down [pin 20 (+) to pin 21 (-)] Input Signal (high shuts down inverter) Maximum Collector Voltage (VDC) Maximum Collector Current (mADC) Maximum Output Voltage @ 5 mADC ON Series m UPS User Instruction Manual...
  • Page 22: Appendix C: Specifications And Characteristics

    Less than 10V normal mode (L-N), less than 0.5V Common mode (N-G) when Surge Voltage Let-Through subjected to C62.41 6kV Cat. A pulse Normal and Common Mode Clamping instantaneous Response Time * ± 2 volt tolerance on all measurements. ON Series m UPS User Instruction Manual...
  • Page 23 0 to 3,000 m (0 to 10,000 ft) Storage Elevation 0 to 15,000 m (0 to 50,000 ft) Size (HxWxL) inches (cm) 3.75” x 7.0” x 17” (9.5 x 18 x 43) Shipping Weights lbs. (kg) 38 (17) ON Series m UPS User Instruction Manual...
  • Page 24: Safety & Approvals

    EN 50081-1 / 01.92 (Generic Emission - Residential, Commercial and Light Industrial) EN 60601-1-2 / 05.93 (Medical equipment) EN 55011 / (ISM Equipment) EN 55022 / 08.94 (ITE Equipment) EN 61000-3-2 / 04.95 EN 61000-3-3 / 01.95 ON Series m UPS User Instruction Manual...
  • Page 25 UL2601-1 (Medical Electrical Equipment, Part 1 General Requirements for Safety) Canada CSA 22.2 EN 60601-1 Medical Electrical Equipment Europe EN60950 Information Technology Equipment as amended by EN 50091-1 Standard for Uninterruptible Power Systems ON Series m UPS User Instruction Manual...