Download Print this page

Specifications; Warranty - Kisae SWXFR1210 Owner's Manual

Sinewave inverter with transfer switch
Hide thumbs Also See for SWXFR1210:

Advertisement

6. SPECIFICATIONS

Note: The specifications are subject to change without notice.
Specification
Inverter
AC Output Power
AC Output Current
AC Surge Power (Peak)
AC Output Voltage/Frequency
AC Output Waveform
Nominal DC Input Voltage
No Load battery draw
DC Input Voltage operating range
Under Voltage Alarm
Under Voltage Alarm Recovery
Under Voltage Shutdown
Under Voltage Shutdown Recovery
Over Voltage Shutdown
Over Voltage Shutdown Recovery
USB
USB Port
AC Transfer Switch
Transfer Time
Transfer Relay Rating
AC Output Port 1 (Hardwired)
AC Output Port 2 (Hardwired)
AC Output Receptacles
Display
Display Panel Port
Inverter Mode
Safety and Environmental
Conformance
EMI / EMC
Agency Markings
Operating Temperature
Storage Temperature
Relative Humidity
Operating Altitude
Weights and Dimensions
Weights
Dimensions (cm)

7. WARRANTY

One Year Limited Warranty:
The limited warranty program is the only one that applies to this unit, and it sets forth all the
responsibilities of KISAE Technology. There is no other warranty, other than those described herein. Any
implied warranty of merchantability of fitness for a particular purpose on this unit is limited in duration to
the duration of this warranty.
This unit is warranted, to the original purchaser only, to be free of defects in materials and workmanship
for one year from the date of purchase without additional charge. The warranty does not extend to
subsequent purchasers or users.
The manufacturer will not be responsible for any amount of damage in excess of the retail purchase price
of the unit under any circumstances. Incidental and consequential damages are specifically excluded
from coverage under this warranty.
This unit is not intended for commercial use. This warranty does not apply to damage to units from
misuse or incorrect installation/connection. Misuse includes wiring or connecting to improper polarity
power sources.
Return/Repair Policy:
If you are experiencing any problems with your unit, please contact our customer service department at
info@kisaetechnology.com or Phone 1-877-897-5778 before returning the product to the retail store.
After speaking to a customer service representative, if products are deemed non-working or
malfunctioning, the product may be returned to the purchasing store within 30 days of original purchase.
120V model
SWXFR
SWXFR
SWXFR
1210
1220
(1000W)
(2000W)
(3000W)
1000W
2000W
3000W
8.3A
16.6A
2000W
4000W
6000W
120VAC / 60 Hz
30A (resistive load)
30A max
30A max
30A max
15A max
20A max
15A max
20A max
20A max
Input Voltage, Output Power
UL 458, CSA C22.2
No. 107.2-01
FCC Part 15 Class B
cETLus
0°C to 40°C (32°F to 104°F)
-20°C to 60°C (-4°F to 140°F)
5-90% noncondensing
Up to 9,843ft (3000m) above sea level
5 kg
5.9 kg
7.0 kg
43.5x23x11.5
54x23x11.5
Page 18
230V model
SWXFR
SWXFR
1230
1210i
1220i
Series
Series
(1000W)
(2000W)
1000W
2000W
25.0A
4.3A
8.7A
2000W
4000W
230 VAC / 50 Hz
Sinewave (<3% THD)
12.5 VDC
< 1.5 ADC
10.5 – 15.5 VDC
11.0/12.1 VDC
11.3/12.3 VDC
10.5/11.8 VDC
12.0/12.6 VDC
15.5 VDC
15.3 VDC
5V, 750 mA
< 30 ms
16A (resistive load)
Not Applicable
NA
16A max
16A(EU), 13A(UK), 10A(AU) max
RJ12 (6 pins)
CE LVD: EN/IEC 62040-1&
IEC61558-2-16
CE EMC: EN/IEC 62040-2
category C1
5 kg
5.9 kg
43.5x23x11.5
SWXFR
1230i
Series
(3000W)
3000W
13A
6000W
CE
7.0 kg
54x23x11.5

Advertisement

loading