Page 2
PLEASE KEEP THIS MANUAL FOR FUTURE REFERENCE Disclaimer While every precaution has been taken to ensure the accuracy of the contents of this guide, KISAE Technology assumes no responsibility for errors or omissions. Note as well that specifications and product functionality may change without notice.
Page 3
IMPORTANT SAFETY INFORMATION This section contains important safety information for the unit. Each time, before using the unit, READ ALL instructions and cautionary markings on or provided with the unit, and all appropriate sections of this guide. The unit contains no user-serviceable parts. See Warranty section for how to handle product issues. DANGER: Fire and/or Chemical Burn Hazard.
• During utility mode, the built-in AC load sensing circuit will automatically reduce charging current if there is a high demand on AC load. This avoids the tripping of the shore circuit breaker. 2. PRODUCT DESCRIPTION The KISAE Abso Inverter-Charger includes the items list below. • Inverter-Charger base unit • Remote Display •...
IC1230150 Remote 1, Remote 2 and AC Input and Output Battery Temperature Sensor Breaker (30A) (BTS) Ports AC Wiring DC Input Terminal + Compartment DC Input Terminal - AC Wire knockouts Front Panel AC Input 1 and 2 AC Output 1 and 2 AC GND bus for AC AC GND bus for AC Input 1 and 2...
Page 7
Preparing for Installation Input AC Source, AC Loads and AC Output Neutral Bonding for IC1220100 Before you begin the installation, be sure to review the Important Safety Instruction on page 3 of this manual and be aware of all safety and electrical codes which must be met in your area.
Page 8
• The DC cables must be copper and must be rated 105°C minimum. • 2000W unit (IC1220100), use minimum 2/0 AWG wire with maximum cable length of 5 feet. • 3000W unit (IC1230150), use minimum 4/0 AWG wire with maximum cable length of 5 feet.
Page 9
• Based on the National Electrical Code requirement, a fuse or circuit breaker with a minimum of 300 ADC is required for IC1220100 and IC244090i, 450 ADC is required for IC 1230150. • Based on the size of your Battery Bank, determine the overall short circuit current rating of the battery bank from the battery manufacturer.
Page 10
AC Output wire of smaller than #12 AWG is used, then the overcurrent protection device will have to be smaller. Follow the electrical and or building code to choose your protection device rating. Installing the Inverter-Charger System WARNING: Electrical Shock Hazard The unit ‘On/Off’...
Page 11
AC Input 2000W (IC1220100) 3000W (IC1230150) 4000W(IC2444090i) Terminals Single Input Dual Input Split Phase Input Single Input Neutral Neutral Neutral Neutral Line Not Applicable Not Applicable Line Not Applicable Line 1 Line 1 Not Applicable Not Applicable Line 2 Line 2 Not Applicable •...
AC Source is not available, the unit will run on battery power and the unit will generate sinewave AC output to maintain and operate the load continuously. Factory Default Setting 2000W 3000W 4000W Setting (IC1220100) (IC1230150) (IC244090i) Inverter SCR set Power Save Battery Type...
Page 13
Battery Type: Three types of battery setting (GEL, AGM and Flooded) are available. See reference battery charging voltage as shown: 2000W, 3000W unit (12V model: IC1220100, IC1230150): Battery Type Absorption Float Equalization 14.4 V...
Page 14
The battery temperature sensor senses the battery temperature and makes adjustments to the charging voltage. 2000W, 3000W unit (IC1220100, IC1230150): Battery Battery Charging Voltage Adjustment from 25 °C normal setting...
Following run times are estimates for reference, based on using different battery bank sizes. Actual run times may vary. 2000W, 3000W unit (IC1220100, IC1230150): Estimate run time on different 12V Battery Bank Size AC Load 60AH 120AH 180AH 240AH 300AH 50 W 11 hrs.
selected feature to your desired setting. Use the ‘+’ and ‘-‘ button to scroll between different set values or setting. Once the desired values or setting is chosen, press ‘ENTER’ button to save the setting or press ‘EXIT’ button to quit the setting without saving.
The limited warranty program is the only one that applies to this unit, and it sets forth all the responsibilities of KISAE. There is no other warranty, other than those described herein. Any implied warranty of merchantability of fitness for a particular purpose on this unit is limited in duration to the duration of this warranty.
Need help?
Do you have a question about the IC1220100 and is the answer not in the manual?
Questions and answers