Page 2
PLEASE KEEP THIS MANUAL FOR FUTURE REFERENCE Disclaimer While every precaution has been taken to ensure the accuracy of the contents of this guide, KISAE Technology assumes no responsibility for errors or omissions. Note as well that specifications and product functionality may change without notice.
1. INTRODUCTION Thank you for purchasing the KISAE True Sinewave Power Inverter. With our state of the art, easy to use design, this product will offer you reliable service by providing AC power and 5V USB power for your home, cabin, boat, RV or Trailer. The Power Inverter can run many AC-powered appliances when you need AC power anywhere.
Status Indicator Display ‘Power/Select’ On/Off button Remote Switch Port (RJ12 Port for optional remote switch) USB Output AC Output GFCI Socket SW2420 (120VAC model) Status Indicator Display ‘Power/Select’ On/Off button Remote Switch Port (RJ12 Port for optional remote switch) USB Output...
Page 6
• The DC cables must be copper and must be rated 105 minimum. Model Minimum Wire Size Recommended Cable Length SW2420, SW2420i AWG # 2 < 5 feet Caution: Use of smaller gauge cable or longer cable length may cause the inverter to shutdown under heavy load.
Page 7
long cable length is required. Chassis Grounding Cable Size: Important: The unit is grounded through the Chassis Ground (ground stud) located near the DC Input terminal and the chassis of the unit has to be grounded properly before use. • For Marine application, the DC grounding cable size may be one size smaller than the minimum size conductor required for the DC current-carrying conductors and the conductor is no smaller than #10AWG.
If AC is not available, check for error code on display or troubleshooting section. The unit is successfully installed and functioning properly. Test the GFCI Monthly: (SW2420 - 120V model only) • Use the following instruction to perform a monthly test of the AC Output GFCI Socket to ensure the GFCI is functioning properly.
Understanding the Error Code Code Condition Corrective Action Input battery voltage is too low and unit Recharge battery immediately and restart unit has shutdown Input battery voltage is too high and unit Check battery voltage or determine if any has shutdown external charger is connected to the battery bank AC output is overloaded or short circuited Check load connected to the output.
Verify the error condition and make correction Status LED is in GFCI on 120V model Check load for Ground Fault and reset the GFCI Amber (SW2420) is tripped AC Output is Load Sense function is Disable Load Sense function by changing the unit turning ON and...
The limited warranty program is the only one that applies to this unit, and it sets forth all the responsibilities of KISAE. There is no other warranty, other than those described herein. Any implied warranty of merchantability of fitness for a particular purpose on this unit is limited in duration to the duration of this warranty.
Page 12
Service Contact Information Email:info@kisaetechnology.com Phone : 1-877-897-5778 www.kisaepower.com Printed in China Page 12 ...