  • Page 1 Sinewave Inverter with Transfer Switch 1000W - 120V (SWXFR1210) 2000W - 120V (SWXFR1220) 3000W - 120V (SWXFR1230) 1000W - 230V (SWXFR1210i) 2000W - 230V (SWXFR1220i) Owner’s Manual             ...
  • Page 2 PLEASE KEEP THIS MANUAL FOR FUTURE REFERENCE Disclaimer While every precaution has been taken to ensure the accuracy of the contents of this guide, KISAE Technology assumes no responsibility for errors or omissions. Note as well that specifications and product functionality may change without notice.
  • Page 3: Table Of Contents

    Table of Contents     INTRODUCTION....................4     PRODUCT DESCRIPTION ................5     INSTALLATION ....................5   UNIT OPERATION................... 10    12  FEATURE SETTING..................    TROUBLESHOOTING ..................14     SPECIFICATIONS ................... 15     WARRANTY..................... 16  ...
  • Page 4: Introduction

    1. INTRODUCTION Thank you for purchasing the KISAE Sinewave Inverter with Transfer Switch unit. With our state of the art, easy-to-use design, this product will offer you reliable service by providing AC power and 5V USB power for your home, cabin, boat, RV, Caravan or Trailer using battery power.
  • Page 5: Product Description

    Status Indicator AC Output Port 2 & 3 Display AC Output strain relief On/Off button AC Ground Select button AC Input strain relief AC Output Port 1 AC Input port Model SWXFR1210 as shown     Page 5    ...
  • Page 6 USB Output AC Wiring Compartment: Status Indicator AC Output Port 2 & 3 Display AC Output strain relief On/Off button AC Ground Select button AC Input strain relief AC Output Port 1 AC Input port Model SWXFR1220 as shown USB Output AC Wiring Compartment: Status Indicator AC Output Port 2 &...
  • Page 7 Preparing for Installation Typical Wiring block diagram of the Power Inverter: DC Disconnect DC Fuse or AC Output Switch Circuit Breaker Inverter with Ports & 12 V Battery Bank Transfer Switch USB Output Unit AC Input AC Input Source 12V Battery Bank: •...
  • Page 8 AC Input Source and AC Branch Breaker: • Standard AC Input wire is required for all the AC connections between the AC source & the AC Input port, and the AC Output ports to load. • For 120V model minimum of #10 AWG AC wire is required, A 30A branch circuit breaker is also required to connect between AC Input source and unit’s AC Input port.
  • Page 9 (not provided) is required to connect between the AC input source and the Inverter. • Remove AC compartment cover by unscrewing the four screws located at the front of the AC compartment cover. SWXFR1210 SWXFR1210i Series Model SWXFR1220...
  • Page 10: Unit Operation

    This configuration does not require AC Output installation. Plug in the AC load to the provided AC output socket. During the by-pass mode, the AC output is limited to 16A. Use of the provided Hardwire AC Output terminal (Port 2). •...
  • Page 11 Status LED Display LED Display Function/Status Green (solid) Green ’12.5’ By-Pass Mode. Display shows battery voltage in DC volts Amber (solid) Green ‘12.5’ Battery Mode, inverter is running, display shows battery voltage in DC volts Amber ‘0.80’ Battery Mode, inverter is running, display shows output power in kW (800W as shown) Amber (flashing) Battery Mode and AC Input is detected and unit will switch to By-Pass...
  • Page 12: Feature Setting

    Input battery voltage is low and Recharge battery as unit will shutdown warning occurs shortly At Battery Mode, AC output load Reduce load connected has sensed high and is close to shutdown limit Internal temperature is high and is Reduce load and check if any ventilation close to shutdown limit of the unit is blocked E08-11...
  • Page 13 Inverter is disabled, unit will not provide backup function when utility power is not available Inverter is set to standby mode with power save mode OFF. Unit will provide backup function when utility power is not available Inverter is set to standby mode with power save mode ON. Unit will provide backup function only when utility power is not available AND the load connected to the output is >10W.
  • Page 14: Troubleshooting

    6. TROUBLESHOOTING To troubleshoot the unit, please note the error code displayed on the main unit and review “Understanding the Error Codes” in section 4. Problem Symptom Solution No output The unit is off Turn unit ON by following the instruction in voltage.
  • Page 15: Specifications

    No AC output. Circuit Breaker is tripped Check load and reset the breaker Status LED is Green No Output. Circuit Breaker is tripped Check load and reset the breaker Status LED is Check error code on display Verify the error condition and make in Amber correction Check AC Load Sense setting...
  • Page 16: Warranty

    The limited warranty program is the only one that applies to this unit, and it sets forth all the responsibilities of KISAE Technology. There is no other warranty, other than those described herein. Any implied warranty of merchantability of fitness for a particular purpose on this unit is limited in duration to the duration of this warranty.