Parameter List - Wolf SM2 Installation And Operating Instructions Manual

Solar module
Table of Contents

Advertisement

Parameters
Parameters
BM
BM-Solar
SOL 01
P 01
SOL 02
p 02
SOL 03
P 03
SOL 04
P 04
SOL 05
P 05
SOL 06
P 06
SOL 07
P 07
SOL 08
P 08
SOL 09
P 09
SOL 10
P 10
SOL 11
p 11
SOL 12
p 12
SOL 13
p 13
SOL 14
p 14
SOL 15
p 15
SOL 16
p 16
SOL 17
p 17
SOL 18
p 18
SOL 19
p 19
SOL 20
p 20
SOL 21
p 21
SOL 22
p 22
SOL 23
p 23
SOL 24
p 24
SOL 25
p 25
SOL 26
p 26
SOL 27
p 27
SOL 28
p 28
SOL SO
p 50
SOL 70
SOL 71
SOL 72
SOL 73
SOL 74
*SOL70 - SOL 74
28

Parameter list

All parameters can be adjusted via the programming module BM
or BM-Solar.
With the BM, access is provided via control level 2 at the menu level
"Contractor → Solar" (see BM operating instructions).
With the BM-Solar, turning the rotary selector enables the parameter
level to be changed (see BM-Solar operating instructions).
Explanation
Start differential solar cylinder 1
Stop differential solar cylinder 1
Collector protection function
Critical collector temperature
Maximum collector temperature
Max. temperature, solar cylinder 1
Assignment, solar cylinder 1
Capturing the heat volume
Pulse generator
Flow rate, solar circuit
Medium selection
BUS feed
Configuration
Speed control, solar circuit pump
Start differential solar cylinder 2
Stop differential solar cylinder 2
Max. temperature, solar cylinder 2
Assignment, solar cylinder 2
Burner blocked during return temp.
raising
Start differential, return temp. raising
Stop differential, return temp. raising
Priority cylinder
Start differential, parallel cylinder op.
Differential temp. bypass operation
Function output A4
Start temp., thermostat function
Stop differential, thermostat function
Tube collector function
Frost protection
Relay test
Analogue input SFS 1
Analogue input SFK 1
Analogue input E 1
Analogue input E 2 (DFG)
Analogue input E 3
At the BM contractor level, the current values of the sensors
connected to the inputs are also displayed. Assignment of inputs
E1 and E3 subject to system configuration.
Setting range
min.
max.
8 K
30 K
3 K
20 K
0 (OFF)
1 (ON)
90 °C
150 °C
100 °C
150 °C
15 °C
90 °C
0
8
0 (OFF)
2
0 l/pulse
99.5 l/pulse
0 l/min.
99.5 l/min.
0
1
0 (OFF)
2 (Auto)
1
11
0 (NO)
1 (YES)
8 K
30 K
3 K
20 K
15 °C
90 °C
0
8
0 s
300 s
8 K
30 K
3 K
20 K
0 (cyl.1)
1 (cyl.2)
20 K
60 K
30 K
100 K
0 (OFF)
2
30 °C
90 °C
5 K
30 K
0 (OFF)
2
0 (OFF)
1 (ON)
1
5
Factory
setting
10 K
5 K
0
110 °C
130 °C
60 °C
0
0
1 l/pulse
1 l/min.
-
-
1
0
10 K
5 K
60 °C
8
0 s
10 K
5 K
0
30 K
15 K
0
50 °C
10 K
0
0
1
3062438_0309