SOL12 / P12
System configuration
3062438_0309
Parameter description
The corresponding system configuration may, subject to the
application of the SM2 solar module, have to be selected.
Eleven system versions with up to two solar cylinders and two
collector arrays are available:
Setting
System
parameters
1
Single circuit system
2 *
Single circuit system with return temperature
raising for central heating backup
3
Dual-circuit system with two solar cylinders in
parallel operation
4
Dual-circuit system with two solar cylinders
with cylinder priority control
5
Dual-circuit system with two collector arrays
and two solar circuit pumps
6
Dual-circuit system with two collector arrays
and one solar circuit pump
7
Dual-circuit system with two collector arrays,
two solar cylinders with cylinder priority control
and two solar circuit pumps
8
Dual-circuit system with two collector arrays,
two solar cylinders with cylinder priority control
and one solar circuit pump
9
Single circuit system with bypass circuit
10
Dual-circuit system with two solar cylinders
with cylinder priority control and bypass circuit
11
Dual-circuit system with two solar cylinders
with parallel cylinder operation and bypass
circuit
The schematic layout of the various systems is illustrated with a
description of the electrical connections relative to the individual
system configurations (chapter "Electrical connection").
* When using the SM2 with connection set CGS / CGW / CGI
(part no. 27 44 465), select system configuration 2.