Iwatsu SS-540 Instruction Manual page 23

Current probe
Table of Contents

Advertisement

Frequency bandwidth
Rise time
Waveform response
Maximum continuous input
current range
Maximum peak current value
Output voltage rate
Amplitude accuracy
Noise
Power consumption
Power supply voltage
Temperature/humidity range
(operating)
Temperature/humidity range
(storaged)
Location for use (operating)
Accuracy warranty period
Product warranty period
Temperature characteristic of
sensitivity
External magnetic field
Measurable conductor
Measurable conductor diameter
Cable or cord lengths
External dimensions
Weight
Accessories
Table2. SS-540 Instrument specifications
DC to 50 MHz (−3 dB)
7 ns or less
Sag: 3 % or less (for 1kHz rectangular waveform)
Overshoot: Within +10 %/-20 % (for the step waveform
30 Arms (See Figure3. Derating by Frequency.)
50 A peak (in the non-continuum)
0.1 V/A
±1.0 % rdg. ± 1 mV : to 30 Arms
±2.0 % rdg.
(for DC or within the range of AC 45 to 66 Hz)
2.5 mArms or less. (for measuring instrument with 20
MHz bandwidth)
5.6 VA or less
DC ±12 V±0.5 V
0 °C to +40 °C (no dew condensation),
below the moisture of 80 % RH
−10 °C to +50 °C (no dew condensation),
below the moisture of 80 % RH
Indoor use, Pollution Degree 2 and at the altitude of
2000 meters or less
1 year (Opening/Closing up to 10,000 times)
1 year
Within ±2 % (for the input of 50 Hz and 30 Arms within
the range of 0 °C to +40 °C)
Equal to 20 mA or less (for DC, 60 Hz, and 400 A/m of
AC magnetic field)
Only for insulated target conductor
φ 5 mm or less
Sensor cable
Power cord
Sensor part: 175 (W) × 18 (H) × 40 (D) mm (±2 mm)
Terminator part: 27 (W) × 55 (H) × 18 (D) mm (±2 mm)
230 g ± 20 g
Instruction manual (1), Soft case (1)
Sheet for China RoHS (1) , Cable tie (1)
in rise time of 3 ns)
: 30 Arms to 50 Apeak
1.5 m ±0.1 m
1.0 m ±0.1 m
Chapter 1 Overview
19

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ss-550Ss-500

Table of Contents