Functional Check And Camera Adjustment; Faults - Ametek Motec MC3000B Installation And Operating Instructions Manual

Heavy-duty camera solution
Table of Contents

Advertisement

Available languages

Available languages

panying self fusing electrical tape. To do this, unwind the tape around the plug
while pulling lightly. In addition to further improving the seal, this will also provide
additional protection for the screw connection and prevent it from accidentally
coming loose. Use new fusing tape if you open the screw connection again later.
Make certain the cables are securely fastened onto the vehicle.
3.3

Functional check and camera adjustment

Check the camera functionality after you have connected it to a monitor. Switch
the camera display to mirror image (see operating manual of monitor/control
unit). Align the camera so that the mandatory field of view is displayed on the
monitor. Tighten the fastening screws on the camera completely. Seal any cable
breakthroughs and check cables that were laid to ensure they are securely in
place. The camera does not have any accessible controls. It is placed in operati-
on by switching on the monitor. For information about the monitor please consult
the corresponding operating manual.
3.4

Faults

If a nonfunction or error is detected during operation, normally the first thing to
do is check the external circuit (fuse, power supply voltage, wiring, monitor etc.).
If the malfunction or or the errors are clearly attributed to the camera, so is this,
send it back together with a description of the fault and the RMA form (www.
motec-cameras.com/en/service/returns), to the factory.