Network dac
Hide thumbs Also See for LINA:
Table of Contents

Advertisement

NOTICE
Heavy or inflexible power cables may damage the power socket on the unit.
Some "audiophile" cables have unusual grounding or screening arrangements, or
they don't have the correct characteristic impedance. If you have difficulty using
such cables but the problem disappears when you use standard cables, contact
your cable manufacturer.
Digital inputs
Input
Recommended cable and connector
AES / EBU
110 Ω screened, twisted pair cables fitted with one male 3 way XLR connector and one
female 3 way XLR connector.
Word Clock
75 Ω coax cables fitted with BNC connectors.
/ SPDIF
BNC
SPDIF RCA
75 Ω coax cables fitted with RCA phono connectors.
Toslink
Toslink fibre-optic cables.
Network
RJ45 Ethernet cable.
USB
Standard screened USB 2.0 cable fitted with one type 'A' connector and one type 'B'
connector. The internal screen must be connected at both ends.
The Word Clock sockets require a simple DC-coupled connection. If you use
capacitor-coupled cables or cables with built-in networks, the interfaces may not
work correctly.
Analogue outputs
Output
Recommended cable and connector
Balanced
Screened, twisted pair cables fitted with one male 3 way XLR connector and one
output
female 3 way XLR connector.
Unbalanced
Coax cables fitted with RCA phono connectors.
outputs