2.3.
FLOOR SENSOR CALIBRAT ION
Floor sensor calibration (an additional icon is displayed:
the floor temperature measured by the sensor differs from the actual temperature.
Calibration setting range is from -9,9 to +9,9 ⁰C with the accuracy of 0,1⁰C.
To calibrate the built-in sensor, press the MENU button until the floor sensor
calibration screen appears. Use the buttons
confirm, press the MENU button (confirm and go on to edit the next parameter).
2.4.
SOFTWARE VERSION
After pressing the MENU button the user may check the software version number. The
number is necessary while contacting the service staff.
2.5.
DEFAULT SETTINGS
This function is used to restore factory settings. In order to do it, change the flashing
digit 0 to 1.
VIII. TECHNICAL DATA
Temperature adjustment range
Power supply
Measurement error
Potential-free cont. nom. out. load
) should be performed if
to set the desired correction. To
EU-297B v3
17
o
o
5
C - 35
C
2xAAA 1,5V batteries
o
+/- 0,5
C
230V AC / 0,5A (AC1) *
24V DC / 0,5A (DC1) **