Technical specifications
Permissible ambient conditions
Ambient temperature
Relative humidity
Operating altitude
Contaminant concentration
Degree of pollution
Degree of protection
Dimensions and weight
Dimensions
Weight
Installation options
Mean time between failure (MTBF)
SCALANCE WxM763
Operating Instructions, 03/2022, C79000-G8976-C653-01
During operation
During storage
During transportation
During operation
During operation
W x H x D
•
Wall mounting
•
Mounting on a DIN rail
direct
–
rotated by 90° with accessories
–
•
Mounting on an S7-300 mounting rail
•
Mounting on an S7-1500 mounting rail
•
Mounting on a pedestal
at 40 °C ambient temperature
-30 °C ... +60 °C
-40 ℃ to +85 ℃
-40 ℃ to +85 ℃
≤ 90% at 25 °C, no condensation
≤ 2000 m above sea level
According to ISA-S71.04.-2013 Class G3
2
IP30
35 x 157 x 137 mm
0.65 kg
26 years
Technical data
73