Description of the device
4.9 Configuration License PLUG
– If the CLP contains a license, additional functions are also enabled.
During operation:
– During operation, changes to the configuration are saved on the CLP and in the
– The configuration data of the device is stored in a secured memory area of the
– The device checks whether a CLP is inserted at one second intervals. If the device
– The device signals deviations from normal operation of the CLP (e.g., incompatible
The procedure for inserting and removing the CLP can be found in the section
"Replacing a CLP (Page 62)".
34
Note
If the device was configured at some time with a CLP license, the device can no
longer be used without this CLP. To be able to use the device again, reset the
device to the factory settings.
internal memory.
CLP. This secured memory area can only be accessed via the authentication of the
Siemens device.
detects that the CLP has been removed, it restarts automatically.
NOTICE
Operating risk - Danger of data loss
Only pull and plug the CLP when the device is de-energized.
data, incorrect operation or malfunctions) via the existing diagnostics mechanisms
(e.g., LEDs or user interfaces).
Operating Instructions, 03/2022, C79000-G8976-C653-01
SCALANCE WxM763