Operating Instructions

Operating Temperature Ranges
Room
Temperature
Outdoor
Temperature
NOTES:
• If the air conditioner operates for extended periods in cooling mode and the humidity
is high (over 80%), condensed water may drip out of the unit. If this occurs, set the vertical
airflow louver to its maximum angle (vertical toward the floor), and set it to HIGH fan mode.
• Optimum performance will be achieved within the above operating temperatures. If the air
conditioner is operated outside of the above temperatures, certain safety protection features
might be activated and cause the unit to function abnormally.
• FOR OUTDOOR UNITS WITH AUXILIARY ELECTRIC HEATER: When the outside temperature
is below 32°F (0°C), we strongly recommend keeping the unit plugged in at all time to ensure
smooth ongoing performance.
Manual Operation (without remote)
CAUTION
The manual control button is intended for testing purposes
and emergency operation only. Please do not use this
function unless the remote control is lost and it is absolutely
necessary. To restore regular operation, use the remote
control to activate the unit. THE UNIT MUST BE TURNED
OFF BEFORE THE MANUAL OPERATION FUNCTION CAN
BE ACTIVATED.
To operate the unit manually, follow these steps:
1. Open the front panel of the indoor unit.
2. Locate the MANUAL CONTROL BUTTON on the
right-hand side of the unit.
3. Press the MANUAL CONTROL BUTTON one time to
activate the FORCED AUTO MODE.
4. Press the MANUAL CONTROL BUTTON a second time to
activate the FORCED COOLING FUNCTION.
5. Press the MANUAL CONTROL BUTTON a third time to
turn the unit off.
6. Close the front panel.
Safety Precautions
COOL Mode
62°F - 90°F
(17°C - 32°C)
12K-24K Capacity
-13°F - 122°F
(-25°C - 50°C)
36K Capacity
5°F - 122°F
(-15°C - 50°C)
mrcool.com
HEAT Mode
32°F - 86°F
(0°C - 30°C)
12K-24K Capacity
-13°F - 75°F
(-25°C - 24°C)
36K Capacity
5°F - 75°F
(-15°C - 24°C)
2
DRY Mode
50°F - 90°F
(10°C - 32°C)
32°F - 122°F
(0°C - 50°C)
Manual control button
Fig 2.1