1MAC254287-MB A
No
61850 Path
event
LD0.FLTMSTA1.MaxAmpsA.mag.f
LD0.FLTMSTA1.MaxAmpsB.mag.f
LD0.FLTMSTA1.MaxAmpsC.mag.f
LD0.FLTMSTA1.MaxAmpsN.mag.f
LD0.FLTMSTA1.AmpsA.mag.f
LD0.FLTMSTA1.AmpsB.mag.f
LD0.FLTMSTA1.AmpsC.mag.f
LD0.FLTMSTA1.AmpsN.mag.f
LD0.FLTMSTA1.AmpsNClc.mag.f
LD0.FLTMSTA1.AmpsNgSeq.mag.f
LD0.FLTMSTA1.VoltsA.mag.f
LD0.FLTMSTA1.VoltsB.mag.f
LD0.FLTMSTA1.VoltsC.mag.f
LD0.FLTMSTA1.VoltsAB.mag.f
LD0.FLTMSTA1.VoltsBC.mag.f
LD0.FLTMSTA1.VoltsCA.mag.f
LD0.FLTMSTA1.VoltsN.mag.f
LD0.FLTMSTA1.VZroSeq.mag.f
LD0.FLTMSTA1.VPsSeq.mag.f
LD0.FLTMSTA1.VNgSeq.mag.f
LD0.FLTMSTA1.PHL1MxDur.mag.f
LD0.FLTMSTA1.PHH1MxDur.mag.f
LD0.FLTMSTA1.EFL1MxDur.mag.f
LD0.FLTMSTA1.DEFL1MxDur.mag.
f
LD0.FLTMSTA1.ROV1MxDur.mag.f
LD0.FLTMSTA1.PHUV1MxDur.mag
.f
LD0.FLTMSTA1.PSUV1MxDur.mag.
f
LD0.FLTMSTA1.NSOV1MxDur.mag
.f
LD0.FLTMSTA1.MaxTmpRl.mag.f
LD0.MPTTR1.TmpRl.mag.f
*
LD0.MPTTR1.TmpUsed.mag.f
*
LD0.MPTTR1.ThmLevSt.mag.f
*
LD0.MPTTR1.ThmLevEnd.mag.f
Table continues on next page
REM615 ANSI
Point List Manual
Default
Default
Disabled Description
Index
Class
140
0,2
141
0,2
142
0,2
143
0,2
144
0,2
145
0,2
146
0,2
147
0,2
148
0,2
149
0,2
158
0,2
159
0,2
160
0,2
161
0,2
162
0,2
163
0,2
164
0,2
165
0,2
166
0,2
167
0,2
168
0,2
171
0,2
177
0,2
190
0,2
193
0,2
199
0,2
202
0,2
203
0,2
207
0,2
222
0,2
223
0
224
0
225
0
DNP3 data mappings
Maximum phase A current
Maximum phase B current
Maximum phase C current
Maximum residual current
Phase A current
Phase B current
Phase C current
Residual current
Calculated residual current
Negative sequence current
Phase A voltage
Phase B voltage
Phase C voltage
Phase A to phase B voltage
Phase B to phase C voltage
Phase C to phase A voltage
Residual voltage
Zero sequence voltage
Positive sequence voltage
Negative sequence voltage
PHLPTOC1 duration
PHHPTOC1 duration
EFLPTOC1 duration
DEFLPDEF1 duration
ROVPTOV1 duration
PHPTUV1 duration
PSPTUV1 duration
NSPTOV1 duration
PTTR thermal level
THERMLEV
The ambient temperature used in the calculation
Thermal level at beginning of motor startup
Thermal level at the end of motor startup situation
Section 2
Multiplier
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
19

Advertisement

Table of Contents
loading

This manual is also suitable for:

Relion rem615 ansi

Table of Contents