WE-EF LEUCHTEN Installation and Maintenance Instructions Floodlight FLB141 #2 LED Do not open during installation Surge Protection This product is factory-sealed. This product features built-in surge protection circuitry in compliance with Refer to the instructions contained in this applicable standards.
Page 2
Floodlight FLB141 #2 IP66, IK08. Class I. ta = 40°C Weight for FLB141 #2 LED Windage area m² for FLB141 #2 LED 0.0506 Orientation: all directions...
Light Source Maintenance Apart from cleaning the product’s exterior surfaces, no special maintenance work is required. Do not use high-pressure cleaners. In case of component failure due to abnormal circumstances or at end of life, replacement must be carried out Warning: Do not open luminaire while mains supply is switched on.
– DO NOT INSTALL ON WET CONCRETE! Handling: handled with care, scratches and damage to the coated surface can result in galvanic corrosion. A WE-EF warranty does not cover any adverse reaction or damage, due to improper installation and requests that our recommendations are followed.
Installation Procedure 1) Switch off mains electrical supply. 2) Check that rating shown on luminaire label conforms with mains electrical supply. 07/18 IP66 FLB141-LED 220-240V50-60/Hz 161-XXXX SOE XXXXXXX LED 3000K 18W item no. XXX (example) A by loosening screws B. Disconnect terminal connector C. Drill relevant holes E and insert wall plug F.
Page 6
5) Feed mains supply cable G through the pres- 6) Connect mains supply cable G leads to sure screw I respective terminals in terminal connector C: A, insert and a) ON/OFF (L = Phase, N = Neutral, tighten screws D. Ensure nylon washers stay = Earthing) in position.