Water supply

Each water supply line to the machine should
be fitted with a manual shut-off valve and debris
filter to facilitate servicing. Check the local regu-
lations to determine whether non-return valves
are required.
Connection hoses should be of the quality re-
quired according to regulations in the country of
use.
Water pressures:
minimum: 40 kPa (0.4 kp/cm
maximum: 1 MPa (10 kp/cm
recommended: 0.2-0.5 MPa (2-5 kp/cm
Hoses and pipes should be flushed through be-
fore being connected to the machine. Make sure
the hoses have no sharp bends or angles.
The machine can have one or two supply hoses,
DN 20 (R /4'').
Machine with cold water intake only.
5
Machine with hot and cold water intake.
6
Machine with hot and cold water intake, but
7
plumbed for cold only because hot not available.
Both valves must be connected even if there is
only one water supply present.