Pre-Installation Requirements; Electrical Requirements; Grounding Requirements; Water Supply Requirements - Electrolux Frigidaire CTF140FS0 Installation And Safety Instructions

Full size tumble action washer
Table of Contents

Advertisement

Available languages

Available languages

PRE-INSTALLATION REQUIREMENTS

Tools Required for Installation:
1. 1/4 in. nut driver
2. 3/8 in. socket with ratchet.
3. 3/8 in. open end wrench.
4. 7/16 in. socket with ratchet.
5. 9/16 in. open end wrench.
6. Channel-lock adjustable pliers.
7. Carpenter's level.

ELECTRICAL REQUIREMENTS

CIRCUIT - Individual, properly polarized and grounded 15 amp.
branch circuit fused with 15 amp. time delay fuse or circuit breaker.
POWER SUPPLY - 2 wire, with ground, 120 volt, single phase, 60
Hz, Alternating Current. NOTE: The use of this washer with power
created by gas powered generators, solar powered generators,
wind powered generators or and other generator other than the
local utility company is not recommended.
OUTLET RECEPTACLE - Properly grounded 3-prong receptacle to
be located so the power supply cord is accessible when the washer
is in an installed position. NOTE: GFI (Ground Fault Interrupter)
receptacle is not required.

GROUNDING REQUIREMENTS

Improper connection of the equipment grounding
conductor can result in a risk of electrical shock. Check with a
licensed electrician if you are in doubt as to whether the appliance
is properly grounded.
1. The washer MUST be grounded. In the event of malfunction
or breakdown, grounding will reduce the risk of electrical
shock by a path of least resistance for electrical current.
2. Since your washer is equipped with a power supply cord
having an equipment-grounding conductor and a grounding
plug, the plug MUST be plugged into an appropriate, copper
wired receptacle that is properly installed and grounded in
accordance with all local codes and ordinances or in the
absence of local codes, with the National Electrical Codes,
ANSI/NFPA 70 (latest edition). If in doubt, call a licensed
electrician.
DO NOT cut off or alter the grounding prong on the power supply
cord. In situations where a two-slot receptacle is present, it is the
owner's responsibility to have a licensed electrician replace it
with a properly grounded three prong grounding type
receptacle.

WATER SUPPLY REQUIREMENTS

Hot and cold water faucets MUST be installed within 42 inches
(107 cm) of your washer's water inlet. The faucets MUST be 3/4
inch (1.9 cm) garden hose type so inlet hoses can be connected.
Water pressure MUST be between 10 and 120 pounds per square
inch (maximum unbalance pressure, hot vs. cold, 10 psi.) Your
water department can advise you of your water pressure.

DRAIN REQUIREMENTS

Models equipped with drain pump:
1. Drain MUST be capable of eliminating 17 gals (64.3 L) per
minute.
2. A standpipe diameter of 1-1/4 in. (3.18 cm) minimum.
3. The standpipe height above the floor should be:
NOTE:
Drain hose attached to the washer can reach a 58 in. (147 cm)
high standpipe. For higher standpipe use hose P/N 131461201,
available from an authorized parts distributor. If drain is less than
24 in. (61 cm), install a siphon break kit, available at your local
hardware store.
Models equipped with gravity drain:
1. Floor drain MUST be capable of eliminating 17 gals (64.3 L)
per minute.
2. Floor drain diameter must be at least 1/2 inch larger than
drain hose.

LOCATION OF YOUR WASHER

DO NOT INSTALL YOUR WASHER:
1. In an area exposed to dripping water or outside weather
conditions. The ambient
below 60 degrees F (15.6 degrees C) for proper washer
operation.
2. In an area where it will come in contact with curtains or drapes.
3. In an area (garage or garage-type building) where gasoline of
other flammables are kept or stored (including automobiles).
4. On carpet. Floor MUST be solid with a maximum slope of 1/2
in. per foot (1.27 cm per 30.5 cm). To ensure vibration or
movement does not occur, reinforcement of the floor may be
necessary.
IMPORTANT MINIMUM INSTALLATION CLEARANCES
When installed in alcove: Sides, Rear, Top = 0 in (0 cm).
When installed in closet: Sides, Rear, Top = 0 in (0 cm),
Front = 1 in (2.54 cm).
Closet door ventilation openings required: 2 louvers each 60 in
(387 cm²) -
3 in (7.6 cm) from top and bottom of door.
3
3
Max.
Max.
Max.
Max.
Max.
temperature should never be
²

Advertisement

Table of Contents
loading

Table of Contents