8.- SPEAKER: rotating this control modifies the overall output volume. A long press on this control activates
the lock function.
9.- FEEDBACK KILLER: A short press of this button activates/deactivates the feedback suppressor
function. A long press of this button resets the notch filter settings. It is recommended to reset the filter
settings when the feedback blanker function is active and feedback is present.
10.- REC/EXIT: when navigating through the configuration menu, a short press on this button allows you to
return to the start menu.
In playback mode, a short press starts recording to the USB storage device.
11.- REPEAT/ : a short press on this button scrolls down through the different configuration menus. And a
long press on this button allows you to activate/deactivate the simultaneous translation mode.
In playback mode, a short press of this button allows you to change the repeat mode of the files to be
played (normal playback or repeat one).
12.- MONITOR: by rotating this control we modify the volume of the speakers integrated in the base of the
chairman microphones SCD-610P and delegate SCD-620D. A long press on this button allows you to
change the lock password. For more information see section LOCK FUNCTION.
When navigating through the menu, turn this control to scroll through the different menu options.

REAR PANEL

1
2
1.- POWER: on/off switch of the equipment.
2.- Power supply socket.
3.- Connection slot for Dante SCD-640DT module.
4.- RJ-45 port for LAN network connection.
5.- RS485: connection for camera system.
6.- ALARM IN: this input, by means of contact closure, activates the alarm mode of the equipment, muting
all audio sources and microphones and only emitting the incoming signal via INPUT as long as the
alarm function is enabled in the equipment.
7.- MIC INPUT: ports for connection of SCD-610P and SCD-620D microphones, 16 maximum in cascade
per port.
8.- REC OUTPUT: unbalanced audio outputs for external recording, 2 x RCA.
9.- INPUT: Auxiliary line level input, 2 x RCA. If you enable the alarm function, connect the audio output
of the evacuation system to this input to play the message on the equipment which is part of the
conference system when the alarm mode is activated by ALARM IN.
10.- OUTPUT: line level output, 2 x RCA.
11.- MIC INPUT: unbalanced microphone level input with phantom power, XLR connector (pin out: 1-ground,
2-signal and 3-on LED). It will be used as input for simultaneous translation if this function is active. For
more information, see section SIMULTANEOUS TRANSLATION.
1
2
3
Discuss Mode /
Voting
(Push&Hold 3S)
USB
Feedback K er
9
3
4
4
5
6
7
Play / Pause
Stop
PRE /
Next / w
EQ
(Push&Hold 3S)
REC / Exit
Repeat / s
10
11
12
5
6
7
- 3 -
8
SPEAKER
MONITOR
8
9 10
11
EN

Advertisement

Table of Contents
loading

This manual is also suitable for:

Scd-610pScd-620dScd-630ext

Table of Contents