EBARA DML Instruction Manual page 8

Table of Contents

Advertisement

(1) Under no circumstances should the cable be
pulled while the pump is being transported or
installed. Attach a chain or rope to the grip and
install the pump.
(2) This pump must not be installed horizontally.
Ensure that it is installed upright on a secure
base.
(3) Install the pump at a location in the tank where
there is the least turbulence.
(4) If there is a flow of liquid inside the tank,
support the piping to prevent abnormal
vibration. (See Fig.2)
(5) Install piping so that air will not stagnate
(6) Do not permit end of discharge piping to be
submerged. A backflow will result when the
pump is stopped.
(7) Manual type pumps do not have an automatic
operating system based on built-in floats. Do
not operate the pump more than ten minutes
with the water level near the minimum
operating level as the automatic cut-off switch
incorporated inside the motor will be activated.
To avoid dry operation, install an automatic
operating system, as shown in Fig.3.
Water levels H1 and H2 are shown in the
following table.
(8) When using electrodes for automatic operating
system, incorrect actuation may occur caused
by scum and oil attached on the electrodes.
Frequency
H2(mm)
DML
50Hz
H1(mm)
H2(mm)
DML
60Hz
H1(mm)
Frequency
H2(mm)
DMLV
50 Hz
H1(mm)
(9) Installation of the pump with quick discharge connector shall be performed according to the
manual "Quick Discharge Connector "
Packing materials after installation, and wasted lubricant oil and grease, and parts after
Note
inspection and repair shall be transferred to a qualified waste-treatment contractor observing
the applicable laws and the regional regulations.
Install a stand-by pump preparing for an accidental stop of the operating pump.
Caution
There is a possibility of suspension of water supply to stop the facilities.
2.2kW
3.7kW
5.5kW
547
627
724
279
279
310
547
627
707
279
279
294
2.2kW
3.7kW
5.5kW
560
620
760
200
200
250
- 8 -
Pipe
support
Fig.2
Fig.3
7.5kW
11kW
15kW
724
778
778
310
329
329
707
771
771
294
322
322
7.5kW
11kW
15kW
760
810
810
250
250
250
EBARA
22kW
841
342
828
329
22kW
865
250
Corporation