Siemens SIMATIC NET SCALANCE W760 Operating Instructions Manual page 39

Hide thumbs Also See for SIMATIC NET SCALANCE W760:
Table of Contents

Advertisement

NOTICE
Damage to the device due to potential differences
To fully eliminate the influence of electromagnetic interference, the device must be
grounded. There must be no potential difference between the following parts, otherwise
the device or other connected device could be severely damaged:
• Housing of the SCALANCE W device and the ground potential of the antenna.
• Housing of the SCALANCE W device and the ground potential of a device connected
• Housing of the SCALANCE W device and the shield contact of the connected
Connect both grounds to the same foundation earth or use an equipotential bonding
cable.
Safety notices on use in hazardous areas
General safety notices relating to protection against explosion
EXPLOSION HAZARD
Do not connect or disconnect cables to or from the device when a flammable or
combustible atmosphere is present.
EXPLOSION HAZARD
Do not press the reset button if there is a potentially explosive atmosphere.
Unsuitable cables or connectors
Risk of explosion in hazardous areas
• Only use connectors that meet the requirements of the relevant type of protection.
• If necessary, tighten the connector screw connections, device fastening screws,
• Close unused cable openings for electrical connections.
• Check the cables for a tight fit after installation.
SCALANCE W760 / W720
Operating Instructions, 03/2022, C79000-G8976-C322-13
over Ethernet.
Ethernet cable.
WARNING
WARNING
WARNING
grounding screws, etc. according to the specified torques.
Connection
6.1 Safety when connecting up
39

Advertisement

Table of Contents
loading

This manual is also suitable for:

Simatic net scalance w720

Table of Contents