2. Express Wizard for Basic Settings

LAN Connection Setting
You have to know the IP address to connect to the 2N Access Unit configuration interface
successfully. Automatic IP address retrieval from the DHCP server is set by default in
the 2N Access Unit. Thus, if connected to a network in which a DHCP server configured to assign
IP addresses to all new devices is available, the device will obtain an IP address from the DHCP
server. The 2N Access Unit IP address can be found in the DHCP server status (according to the
MAC address given on the production plate), or will be communicated to you by the 2N Access
Unit voice function; refer to the Installation Manual.
If there is no DHCP server in your LAN, use the 2N Access Unit RESET button to set the static IP
address mode; refer to the respective Installation Manual. Your unit address will then
be 192.168.1.100. Use it for the first login and then change it if necessary.
Now enter the IP address into your favourite browser. We recommend you to use the latest
Chrome, Firefox or Internet Explorer (Edge) versions as 2N Access Unit is not fully compatible
with earlier browser versions.
Use the name "admin" and password "2n" (i.e. default reset password) for your first login to the
configuration interface. We recommend you to change the default password upon your first
login; refer to the Password parameter in the Services / Web Server menu. Remember the
password well or put it down. It is because if you forget the password, you will have to reset the
intercom to default values (refer to the respective Installation Manual) thus losing all your
current configuration changes.
Tip
Installation manual:
2.3 Electric Installation
Firmware Update
We also recommend you to update your firmware upon the first login to the device. Refer
to www.2n.cz for the latest firmware version. Press the Update Firmware button in the System/
Maintenance menu to upload firmware. The device will get restarted upon upload and only
then the updating process will be complete. The process takes about 1 minute.
Electric Lock Switching Settings
An electric door lock can be attached to the 2N Access Unit and controlled by a code from the
numeric keypad. Connect the electric lock as instructed in the respective Installation Manual.
4 /  134