Evident SZX-AR1 Instructions Manual

Hide thumbs Also See for SZX-AR1:
Table of Contents

Advertisement

Quick Links

Instructions
SZX-AR1 System
Note
This instruction manual is for the our SZX-AR1 System.
To ensure safety, obtain optimum performance and to familiarize yourself fully with the use of this
product, we recommend that you study this manual thoroughly before operating the product,
Optical Microscope and Accessory
For details about the products included in the configuration of this system, see page 17.
A M 5 1 8 6

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SZX-AR1 and is the answer not in the manual?

Questions and answers

Summary of Contents for Evident SZX-AR1

  • Page 1 SZX-AR1 System Note This instruction manual is for the our SZX-AR1 System. To ensure safety, obtain optimum performance and to familiarize yourself fully with the use of this product, we recommend that you study this manual thoroughly before operating the product, Optical Microscope and Accessory For details about the products included in the configuration of this system, see page 17.
  • Page 2 This product is applied with the requirements of standard IEC/EN61326-1 concerning electromagnetic compatibility. - Emission Class A, applied to industrial environment requirements. - Immunity Applied to industrial environment requirements. Some interference may occur if this product is used in domestic location. NOTE: This product has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules.
  • Page 3: Table Of Contents

    SZX-AR1 System Contents Concept of this instruction manual .........................1 Product Concept ..................................3 Safety precautions .................................4 Handling precautions................................6 System requirements for the PC ........................11 1 Setup workflow ..................................12 2 Unpacking and packing procedures ....................13 Unpacking procedure ....................................... 13 Packing procedure .........................................14 3 Maintenance and storage ..........................
  • Page 4 7-4 Observation and acquisition with camera ....................24 7-5 Setting up the software ................................ 25 Starting the system ........................................25 Setting up Windows ......................................25 Setting up the software ....................................26 Configuring the microscope system ..............................26 Performing the parfocal adjustment of the camera .....................27 Adjusting the AR image view ...................................27 Setting the zoom magnification sensor ............................29 7-6 Operating the AR tilting trinocular tube ......................
  • Page 5 SZX-AR1 System 11 List of observation magnifications and observation ranges .......45 12 Software ....................................46 12-1 Installation ....................................... 46 Installing the software ......................................46 Installing the device driver for DP23/DP28 ..........................47 Installing the device driver for DP27 ..............................48 12-2 Uninstalling ....................................49 Uninstalling the software ....................................49...
  • Page 6: Concept Of This Instruction Manual

    SZX-AR1 System Concept of this instruction manual This instruction manual describes the contents related to the whole SZX-AR1 system. Target group This instruction manual is intended for users who use the product according to “Intended use” on page 3, and for our distributors.
  • Page 7 How to read this instruction manual This instruction manual is created as follows. Title in first layer Title in second layer GX53 OOOOOOOO OOOOOOOOOOOOOOOOOOOOOOOOOOOOO 6-1 OOOOOOOOOO Title in third layer OOOOOOOOOOOOOOOOOOOOOOOOOOOOO OOOOOOOOOO Operating procedure Loosen the clamping screw with a screwdriver..
  • Page 8: Product Concept

    SZX-AR1 System Product Concept Product outline The SZX-AR1 system can superimpose the digital contents as Augmented Reality on the image observed through the eyepieces of the stereo microscope. Intended use Use cases for this product · Assembly and inspection work in manufacturing processes ·...
  • Page 9: Safety Precautions

    Safety precautions If the product is used in a manner not specified by this manual, the safety of the user may be imperiled. In addition, the product may also be damaged. Always use the product according to this instruction manual. Prevention of electric shock ·...
  • Page 10 SZX-AR1 System Safety symbols The following symbols are placed on this product. Study the meaning of the symbols and always use the product in the safest possible manner. Symbol Meaning Indicates a non-specific general hazard. Follow the cautions given after this symbol or in the instruction manual.
  • Page 11: Handling Precautions

    Handling precautions General precautions · This product is a precision instrument. Handle it with care and avoid subjecting it to a sudden or NOTE severe impact. · Disassembling the product could cause unexpected accidents or failure. Never disassemble the product. ·...
  • Page 12 SZX-AR1 System · When the zoom magnification sensor is attached, minor scratches may be made on the focus adjustment knob. · The magnification indicated on the focus adjustment knob may be different from the total magnification on the software in the following cases. To avoid this confusion, remove the magnification indication sticker or the magnification ring attached to the focus adjustment knob before use.
  • Page 13 Load capacity of focusing unit Load capacity of focusing unit Product name Load capacity [kg] Focusing unit SZX2-FO Coarse/fine focusing unit SZX2-FOF Standard stand SZ2-ST Weight of each unit Weight of each unit Weight Weight Category Product name Category Product name [kg] [kg] AR tilting trinocular tube...
  • Page 14 1) Change in settings caused by applying OS service pack, security patch, or updating third party software including runtime libraries 2) Change in settings caused by installation of software other than SZX-AR1-APP or version upgrades · If a problem occurs in the system due to a change in the PC environment or inappropriate actions by a third party, we are not responsible for a full recovery to the environment before the event occurred.
  • Page 15 · We are not responsible for indemnity/compensation for loss of profit due to the occurrence of such incidents as the falsification or destruction of confidential information due to the loss of information in the PC or external memory device (HDD, SSD, etc.) due to threats, such as of unauthorized direct or physical interference by a third party with the instrument.
  • Page 16: System Requirements For The Pc

    SZX-AR1 System System requirements for the PC · The PC used with this system should be conformed to IEC/EN60950-1 or IEC/EN62368-1. · The system requirements for the PC used with this system are listed below. Even though the following mentioned recommended operating environments are satisfied, it does not necessarily guarantee the functions of combination use with all commercially-available PCs.
  • Page 17: Setup Workflow

    Setup workflow This section describes the preparation and setting orders to use the SZX-AR1 system. This section also describes the usage and adjustments related to the assembly procedure. Be sure to operate the procedure in the order from the top. Remove the units in the reverse order. (The procedures marked with an asterisk (*) are not necessary for removal.)
  • Page 18: Unpacking And Packing Procedures

    SZX-AR1 System Unpacking and packing procedures Unpacking procedure When you unpack the package, the product and units are packed in plastic bags. However, in this section, to make the explanation and illustration easy to understand, the photos showing the status where these items are taken out from the plastic bags are used.
  • Page 19: Packing Procedure

    Packing procedure Before performing procedures in this section, attach the eyepiece caps and the cap of the straight tube to mount the camera adapter. Before packing the AR tilting trinocular tube, minimize the interpupillary distance of the eyepiece mount and set the tilting angle to the lowest point.
  • Page 20 SZX-AR1 System Insert the clamp of the zoom magnification sensor and the zoom magnification sensor into their respective positions. At this time, insert the zoom magnification sensor into the bottom pad with the larger diameter side facing down. Place the top pad...
  • Page 21: Maintenance And Storage

    Maintenance and storage Lifetime The lifetime of this system is 5 years after purchase if the product is used properly according to this instruction manual. When using SZX2-ARTTR with the unit you are using, follow the lifetime of the unit you are using. Contact us for any questions.
  • Page 22: System Diagram

    SZX-AR1 System System diagram This section shows the SZX-AR1 system diagram in combinations with the SZX-ZB7 zoom microscope body, SZX2-ZB10 zoom microscope body, and SZX2-ZB16 zoom microscope body. If you use this system in combination with any other units than those shown in this system diagram, the product performance cannot be assured.
  • Page 23: System Diagram In Combination With The Szx2-Zb10 Zoom Microscope Body

    System diagram in combination with the SZX2-ZB10 zoom microscope body DP23-CU DP28-CU : ESD compatible unit. DP27-CU Camera head** Camera head** Camera head** : There is a limitation to use with this unit. See the * notes below for details. *1 : SZX2-ILLC10 cannot be combined with DFPL2X-4.
  • Page 24: System Diagram In Combination With The Szx2-Zb16 Zoom Microscope Body

    SZX-AR1 System System diagram in combination with the SZX2-ZB16 zoom microscope body : ESD compatible unit. DP28-CU DP27-CU DP23-CU Camera head** Camera head** Camera head** : There is a limitation to use with this unit. See the * notes below for details.
  • Page 25: Nomenclature Of Main Operation Parts

    Nomenclature of main operation parts This section explains the main parts and nomenclature of the units that constitute the product. AR image brightness adjustment button AR image ON/OFF button Power switch Eyepoint height adjustment knob Diopter adjustment ring ±5 m (per meter) Coarse focusing knob Tension adjustment ring...
  • Page 26: Observation Procedure

    SZX-AR1 System Observation procedure Always hold the binocular section with both hands NOTE to adjust the interpupillary distance. Applying excessive force further beyond the stop position could damage the binocular section. Turn on power to the illumination unit you are using to turn on the light.
  • Page 27: Operation Procedure Of Each Unit

    Operation procedure of each unit 7-1 Stand Using the stage plate Make the white surface or the black surface of the stage facing up according to the sample, and use the one that is easier to observe the sample. Placing the sample Place the sample almost in the center of the stage plate.
  • Page 28: Observation Tube

    SZX-AR1 System When using in combination with the standard base SZ2-ST Looser Lower the focusing unit to the lowest position. Hold the left and right focusing knobs with both hands. Rotating Keep still the right knob while fixing the left knob makes the tension heavier or lighter in the direction you rotate.
  • Page 29: 7-4 Observation And Acquisition With Camera

    7-4 Observation and acquisition with camera You can attach a digital camera to the observation tube using a camera adapter. (Only the DP23, DP27 and DP28 digital cameras can be attached.) For details, refer to the instruction manual for respective camera. The observation ranges on the sample surface through the eyepieces and with the camera when used with the 1x objective lens, a zoom magnification of 1x, and without the coaxial reflected light illumination unit are listed below.
  • Page 30: Setting Up The Software

    Set the power switch of the AR tilting trinocular tube to (ON). Click the SZX-AR1 icon to start the application. Setting up Windows Display a list of programs. Select in the order of the [Start] button, [Settings], [System], and [Display].
  • Page 31: Setting Up The Software

    Setting up the software Select the language you want to use from the [Language] pulldown list on the Home screen. (English is selected by default.) That language will be selected automatically the next time you start the software. Select ON or OFF from the [App. auto startup] pulldown list on the Home screen.
  • Page 32: Performing The Parfocal Adjustment Of The Camera

    SZX-AR1 System Performing the parfocal adjustment of the camera Click [Setup] on the Home screen. Place the sample and look through the eyepieces to bring the sample into focus. For details, see “6 Observation procedure” on page 21 Select the [Confocality Adjustment] tab.
  • Page 33 Operate with the key board. Press “2” of the keyboard and look through the eyepieces to make sure that the cursor appears on the AR image. Make the zoom magnification displayed on the software match SZX-AR the magnification indicated on the focus adjustment knob. Adjust the brightness of the AR image and each illumination unit and the aperture of the AS unit so that both the AR image and the...
  • Page 34: Setting The Zoom Magnification Sensor

    SZX-AR1 System Setting the zoom magnification sensor Make the zoom magnification displayed on the soft- NOTE ware match the magnification indicated on the focus adjustment knob. To use the zoom magnification sensor correctly, you need to enable the click stop. See “Attach- ing the zoom magnification sensor”...
  • Page 35: 7-6 Operating The Ar Tilting Trinocular Tube

    · If the zoom magnification sensor is disconnected from the PC after the software started, reconnect the cable and restart the software. While the SZX-AR1 system is running, if you rotate the focus adjustment knob, the zoom magnification is automatically detected and displayed on the software.
  • Page 36: Connecting The Barcode Reader

    SZX-AR1 System 7-8 Connecting the barcode reader Perform this operation when the setup of the barcode reader (installation of the driver, etc.) is completed. When setting the barcode, set the end of the data (suffix) to Enter (CR). For details, refer to the NOTE instruction manual for the barcode reader.
  • Page 37: Connecting The External Switches

    7-9 Connecting the external switches You can assign shortcut keys built in the software to external switches. Perform this operation when the setup of external switches (installation of the driver, etc.) is completed. Connect the external switch to the PC. Assign the necessary functions to external switches by referring to the list of shortcut keys shown below.
  • Page 38: Troubleshooting

    SZX-AR1 System Troubleshooting This section describes the possible problems on this product and their countermeasures. If problems occur, please review the following list and take remedial action as needed. Problem Cause Remedy Page 1. The left and right The interpupillary distance is Align the interpupillary distance correctly.
  • Page 39 Problem Cause Remedy Page 9. No AR image appears. The AR image is hidden. Turn on the power switch for the AR tilting The AR image trinocular tube and press the AR image disappears. ON/OFF button to show and hide the AR image.
  • Page 40: Specifications

    SZX-AR1 System Specifications This section describes the detail specifications such as the shape, functions, and performance of the product. For details about the PC, see “System requirements for the PC” on page 11. Hardware specifications Item Specifications AR tilting trinocular tube...
  • Page 41 Software specifications Item Specifications Camera control function Exposure control: Switching between Auto and Manual ISO sensitivity adjustment: ISO100, 200, 400 White balance adjustment function: Equipped. (one-touch adjustment) Acquisition function Snapshot acquisition Save format: BMP, JPEG, PNG Resolution: P23 3088 x 2076 DP27 2448 x 1920 DP28 4104 x 1920 The camera image can be saved with the AR image simultaneously.
  • Page 42: Assembly Procedures

    SZX-AR1 System 10 10 Assembly procedures This section describes the procedure to assemble each unit to the zoom microscope body. 10-1 Assembly diagram This section describes where and in which order to attach which units to the zoom microscope body.
  • Page 43: Detailed Assembly Procedure

    10-2 Detailed assembly procedure This section explains the detailed procedures to assemble the zoom microscope body and respective units. For procedures to attach the columns, focusing units, etc., refer to the instruction manual of SZX7 / SZX10 / SZX16. The procedure to remove each unit is in the reverse order of the procedure explained below. For the extendable eyepoint adjuster SZX2-EEPA, standard base SZ2-ST, coarse/fine focusing unit CAUTION SZX2-FOF and focusing unit SZX2-FO, rotate the knob to lower them to the lowest position before...
  • Page 44: Attaching The Ar Tilting Trinocular Tube

    SZX-AR1 System Attach the clamp to the focus adjustment knob (left side of the microscope). Insert the clamp until the position where the end surfaces of the clamp and the focus adjustment knob are aligned when viewed from the front.
  • Page 45: Attaching The Eyepieces

    Attaching the eyepieces Remove the eyepiece caps and sufficiently loosen the eyepiece clamping knobs Insert the eyepieces with the same magnification carefully all the way into the left and right eyepiece sleeves. With the standard scale of the diopter correction ring on the eyepiece facing up, tighten the eyepiece clamping knob on both eyepieces.
  • Page 46: System Wiring

    SZX-AR1 System 10-3 System wiring · When wiring cables, set the main switch of the AR tilting trinocular tube to (OFF). NOTE · Be sure to connect the cable specified by us to each connector. · When connecting each connector, align the orientation of the connector correctly and insert it securely.
  • Page 47: Connecting The Power Supply

    Connecting the power supply · Always use the AC adapter and power cord provided by CAUTION us. If the proper AC adapter and the power cord are not used, the electric safety and the EMC (Electromagnetic Compatibility) performance of the product cannot be assured.
  • Page 48: Routing The Cables

    SZX-AR1 System Routing the cables The basic cable routing is shown below. Route the cables as illustrated below. · If necessary, bundle three cables connected to the back of the AR tilting trinocular tube, one USB cable connected to the zoom magnification sensor, and one USB cable connected to the camera at the lower back of the stand using the cable tie or spiral tube provided with the AR tilting trinocular tube.
  • Page 49: Connecting The Power Outlet

    Connecting the power outlet Insert the power plug into the power outlet The illustrations above are examples for Japan. The plug shapes vary depending on regions and countries.
  • Page 50: List Of Observation Magnifications And Observation Ranges

    11 11 SZX-AR1 System List of observation magnifications and observation ranges The observation magnifications and observation ranges when using this system are shown below. Combination with SZX-ZB7 zoom microscope body (zoom magnification of the zoom microscope body: 0.8 to 5.6X)
  • Page 51: Software

    Double-click the downloaded file and then double-click setup.exe (or setup) in the following folder:   [Mount destination folder]: \SZX-AR1-APP\ When the screen indicating to restart the PC after installation appears, click the [OK] button. Close all running applications. NOTE...
  • Page 52: Installing The Device Driver For Dp23/Dp28

    SZX-AR1 System Select the [ I accept the terms of the license agreement ] radio button, and click the [Next] button. When the completion screen appears, installation is completed. Click the [Finish] button. When the restart confirmation screen appears, click the [OK] button to restart the PC.
  • Page 53: Installing The Device Driver For Dp27

    The [UC480 Drivers - InstallShield Wizard] window appears. Click the [Next] button. The [Ready to Install the Program] window appears. Click [Install]. After the installation is completed, the [InstallSHield Wizard Completed] window appears. Click the [Finish] button. Restart the PC. Installing the device driver for DP27 To install the device driver for DP27, you need to connect NOTE...
  • Page 54: 12-2 Uninstalling

    SZX-AR1 System Installing the analysis application by downloading from Website: Access the URL below and download this software file: https://www.olympus-ims.com/service-and-support/downloads/ 2 2 2 Double-click the downloaded file and then double-click the bat file in the following folder: [Mount destination folder]: DPDriver\DP27\DriverInstall64.bat The black screen appears, and the installation of the device driver starts.
  • Page 55: Uninstalling The Device Driver For The Ar Tilting Trinocular Tube

    When uninstallation starts, the progress screen appears. Click the [Complete] button. Uninstalling the device driver for the AR tilting trinocular tube Display a list of programs. Select in the order of the [Start] button, [Settings], and [Apps & features]. From the program list, select [Windows Driver Package - OLYMPUS CORPORATION (CYUSB3) USB] and click the [Uninstall] button.
  • Page 56: Uninstalling The Device Driver For The Camera

    SZX-AR1 System Uninstalling the device driver for the camera Display a list of programs. Select in the order of the [Start] button, [Settings], and [Apps & features]. For DP27 Select [Windows Driver Package (DP2USB3) USB3Cam] from the program list and click the [Uninstall] button.
  • Page 57: 12-3 Update The Software

    Double-click the downloaded file and then double-click setup.exe (or setup) in the following folder:   [Mount destination folder]: \SZX-AR1-APP\ When the screen indicating to restart the PC after update appears, click the [OK] button. Close all running applications. NOTE...
  • Page 58 SZX-AR1 System Select the [ I accept the terms of the license agreement ] radio button, and click the [Next] button. When the completion screen appears, update is completed. Click the [Finish] button. When the restart confirmation screen appears, click the [OK] button...
  • Page 59: 12-4 Collecting Log Files

    Press the Windows key of the keyboard or use the mouse to click the [Start] button in the Taskbar. Select [OLYMPUS SZX-AR1] from the program list and right-click [Log Collection Tool]. Select [Other] > [Run as Administrator] from the menu displayed.
  • Page 60 SZX-AR1 System When the message to start collecting information appears, if you agree, click the [OK] button. The information collection starts. Information to be collected is listed below. The information collection starts. Information to be collected is listed below. · Software-related logs and configuration file ·...
  • Page 61: Check Sheet When Setting Up The Product

    13 13 Check sheet when setting up the product Be sure to check the following items after setting up the product. If you do not check the following items, the instrument may not exhibit full performance. Check item Impact caused by not checking Check Page The magnification...
  • Page 62 This product is manufactured by EVIDENT CORPORATION effective as of Apr. 1, 2022. Please contact our "Service Center" through the website shown in this manual for any inqui- ries or issues related to this product. EVIDENT CORPORATION 6666 Inatomi, Tatsuno-machi, Kamiina-gun, Nagano 399-0495, Japan この製品は2022年4月1日より...