Page 1
Digital Microscope Hardware Note Thank you for emplying Evident Digital Microscope. To ensure safety, obtain optimum performance and to familiarize yourself fully with the use of this product, we recommend that you read this manual thoroughly before operating this product, and always keep this manual at hand during operatiion.
Page 2
This product is applied with the requirements of standard IEC/EN61326-1 concerning electromagnetic compatibility. - Emission : Class A - Immunity : Industrial electromagnetic environment. Emissions exceeding the level required by aforementioned standards may occur if this product is electrically connected to other equipment. Some interference may occur if this product is used in residential environments.
DSX2000 Contents 1. About this Instruction Manual 1.1 Applicable user of this instruction manual 1.2 Structure of instruction manuals 1.3 How to read this instruction manual 2. Product concept 2.1 Product Overview 2.2 Intended Use 2.3 Trademarks 2.4 Using open source software 3.
Page 4
DSX2000 7. Maintenance and Storage 7.1 Cleaning each part 7.2 Cautions after use 7.3 Lifetime 8. Assembly Procedures 8.1 Assembly Diagram 8.2 Detaching/Attaching Transportation Locks from Frame 8.3 Attaching and removing the Zoom Head 8.4 Attaching/Removing Attachment of the stage 8.5 Attaching/Detaching Nosepiece...
DSX2000 About this Instruction Manual This instruction manual describes the contents related to the whole DSX2000 system. 1.1 Applicable user of this instruction manual This instruction manual is intended for users operating the product according to "Intended Use " (page 3) and for EVIDENT distributors.
DSX2000 1.3 How to read this instruction manual This instruction manual is structured as follows. First level title Second level title Third level title Operating procedure ... indicates the operating procedure..refers to operating portion. Cautions and references The following symbols are used in this instruction manual.
DSX2000 Product concept 2.1 Product Overview This product is a next-generation digital microscope that covers a wider range of magnifications, equipped with a variety of observation methods and image processing capabilities. We provide "Smart Analysis," which eliminates the annoyance of existing optical microscopes and digital microscopes, and enables anyone to quickly and easily observe, measure, and analyze.
DSX2000 Safety Precautions If the product is used in a manner not specified by this manual, user safety cannot be guaranteed and the product may also be damaged. If the product is used in a manner not specified by the manufacturer, the protection provided by the equipment may be impaired.
Page 9
DSX2000 When transporting the frame, do not carry it in an unstable position. When transporting the motorized stage, remove theplate. See"Attaching/Removing Attachment of the stage " (page 36) for how to detach. When transporting the motorized stage, hold the surface of the stage (the part painted gray).
If necessary, you may need to purchase local controller alone. · In some areas, there may be no Evident service system in place. In that case, you may need to send the product to Japan for repair or other services.
If foreign objects such as accessories or metal pieces get into the system through a vent hole or elsewhere, it may cause electric shock or system failure. In such case, immediately stop using the system, turn off the power, and contact the Evident distributor where you purchased the system.
DSX2000 Do not use damaged power cords. This may cause a short circuit or fire. Do not connect the power cord to any power supply voltage other than that specified in the instruction manual. There is a risk of fire, electric shock, or falure.
DSX2000 3.6 Prevention of injury Do not place your hands under the microscope body. You may get your fingers or hand pinched. C A U T I O N Be careful not to get your hands pinched in the microscope body, or cut on the edges of the device.
Page 14
DSX2000 Be careful not to pinch your fingers or hands between the stage and frame when assembling the manual stages. You may get injured if your fingers get pinched in the openings in the stage. When using the polarized illumination adapter, do not touch any part of the adapter other than the adjustment lever.
DSX2000 3.7 Safety-related labels on the product The following symbols are placed on this product. Study the meaning of the symbols and always use the product in the safest possible manner. Mark Meaning Indicates a non-specific general hazard. Follow the description given after this symbol or in the instruction manual.
Page 16
DSX2000 Stage mount Stage back view Control box DSX20-CB Stage front view Label position Label Instructions in instruction manual "Electric shock prevention " (page 6) "Electrical safety " (page 7) "Prevention of injury " (page 9) 3. Safety Precautions 3.7 Safety-related labels on the product...
If you use the controller that has not been tested by Evident for operation, its proper operation cannot be guaranteed. For controller models tested by Evident for operation, contact your distributor.
DSX2000 Note if you exit the application using the [End Process] button on the [Task Manager] dialog box in Microsoft Windows, the last window settings are not saved. If the virus search, sleep function, screen saver, etc. are activated while operating this system, the data acquisition may fail or the system operation may become unstable.
When you need to pack this product, such as to send it to a distant location, you will need a packing box exclusively for this purpose. Always contact an Evident distributor. When observing samples containing hazardous substances, comply with all applicable laws, regulations and handling rules for the environment this product is being used.
DSX2000 Specifications 5.1 Hardware function Unit name Specifications Zoom head Universal zoom head with Zoom ratio 10:1 Number of objectives attachable : motorized 4 objectives revolving nosepiece Observation method : DSX20-MZH Bright field observation Darkfield observation Simultaneous bright/dark field observation Differential interference observation...
Page 21
DSX2000 Cooling : Peltier cooling Scan method : Progressive scan method Frame rate: Maximum 60 fps *When outputting from camera Resolution (For live image) : High 1500x1500(1:1), 2048x1500(4:3) High (Binning 2x2) 1500x1500(1:1), 2048x1500(4:3) 3840x2160(16:9) Super high 3000x3000(1:1), 4096x3000(4:3) Full HD 1920 x 1080...
Page 22
DSX2000 Motorized XY stage with XY stroke: ±50mm from the center transmitted illuminator DSX20-TMTS Long X stroke motorized X stroke: ±100mm from the center Y stroke: ±50mm from the center XY stage DSX20-LMTS Stage Adapter Adapter for manual stage Dedicated for manual stage U-SIC4R2...
DSX2000 Analysis Application Media type: DVD PV-3DAA USB license key Calibration Sample Calibration Sample P50 (50µm x 200 pcs.) DSX-CALS-HR P10 (10µm x 360 pcs.) P3 (3µm x 300 pcs.) Parfocal W.D. Name of objectives N.A. distance (mm) (mm) Long working distance objective lens 3X DSX10-XLOB3X 0.09...
DSX2000 mechanism DSX20-RMTS Motorized Stage with Transmitted 220(W) x 245(D) x 105(H) Illumination DSX20-TMTS X-stroke extension motorized stage 320(W) x 245(D) x 105(H) DSX20-LMTS Tilting Frame 390(W) x 545(D) x 535(H) DSX20-TF Upright frame 390(W) x 545(D) x 400(H) DSX20-UF Long Working Distance Objective Lens 45(H) x 44.9(D)
5.9 Compliant with the Safety and Environment Act Regulations Applicable to the CE:EN61326 ClassA, EN610101-1 System Environmental Standards RoHS (Europe only) Compliant with environmental substance management rules for Evident Group's products 5. Specifications 5.9 Compliant with the Safety and Environment Act...
List of Combinable Units 6.1 Unit Combination There is no compatibility between the DSX1000 and DSX2000 systems. Do not combine them or it may N O T E cause a failure. However, some units can be used in combination. Please see below for the units that can be combined.
Page 30
DSX2000 *3 Long working distance objectives and UIS2 objectives cannot be combined and attached to the DSX20-MZH.The objectives and the sample may collide with each other, so the software is limited to prevent registration with this combination. *4 Objective adapter BD-M-AD is required.
Do not wipe it hard as the sample pattern may be damaged. 7.2 Cautions after use 7.2.1 Storing DSX2000 Store this product in the temperature range of 0 to 40℃. Store this product in the environment without drastic temperature fluctuation (10 °C/h or more).
DSX2000 Assembly Procedures 8.1 Assembly Diagram We recommend having your Evident dealer assemble the product to ensure its performance. When installing, remove any dirt or dust from the attaching portions, and work carefully to N O T E avoid scratches.
Page 33
DSX2000 Installation Flow Chart Unpack the units Also read the included insert. Installation of the frame Removing Transportation Locks from Frame (page 32) When combined with a motorized stage When combined with a manual stage Removing Transportation Locks from Zoom...
Page 34
DSX2000 Detachment Flow Chart Close the application Move the zoom head to the transporting position Shut Down Windows Shut off the power switch Detaching Optional Units Detaching Cartridge Holder (page 47) Detaching Cables (page 49) Detaching Nosepiece (page 42) When combined with a motorized stage...
Page 35
DSX2000 Setting Up the Controller PC Unpacking the Controller PC Connecting the Cables (page 49) BIOS/OS Settings See Instruction Manual Download Site (https://www.olympus-ims.com/user-manuals/) for more information on "Setting Up BIOS and OS for the Controller PC." Installing PRECiV DSX See "Installing and Uninstalling PRECiV DSX" provided with the PRECiV DSX.
DSX2000 8.2 Detaching/Attaching Transportation Locks from Frame · Turning the focus handle without removing the transportation locks may cause damage to the N O T E product. Be sure to remove them. · The transportation locks will be needed when re-shipping the unit, so please keep them in a safe place.
DSX2000 8.3 Attaching and removing the Zoom Head Follow the instructions in this chapter to attach and detach the zoom head. If the product is C A U T I O N attached or detached incorrectly, it may be damaged due to static electricity.
Page 38
DSX2000 Pressing the zoom head, turn it counterclockwise until it stops, and then tighten the fixing screws positions) using the hex wrench provided with the zoom head. Insert the longer end of a hex wrench into the fixing screw and tighten it temporarily, then insert the shorter end of the hex wrench into the fixing screw and tighten it completely.
Page 39
DSX2000 Double-click DSX_packing_software.exe. A dedicated tool will start. Click [Move to lock position for packing] button. The [Confirmation] dialog appears. Confirm the message and then click the [OK] button. The zoom head moves to the transporting position. Click [X] button to close the tool.
DSX2000 8.4 Attaching/Removing Attachment of the stage 8.4.1 Install motorized stage ( DSX20-RMTS, DSX20-TMTS, DSX20-LMTS) · When attaching or detaching the motorized stage, turn off the main switch. N O T E As they are electrically connected, attaching/detaching components while electrified may damage the product to break down.
Page 41
DSX2000 · Operating the stage without removing the transportation locks may cause the product to N O T E breakdown; be sure to detach them. · The transportation locks will be needed when re-shipping the unit, so please keep them in a safe place.
Page 42
If you want to change to the DSX20-RMTS after attaching the manual stage U-SIC4R2 on the frame, you N O T E will need to adjust the frame at our factory. Contact an Evident distributor. To attach or detach the U-SIC4R2, or to change from the U-SIC4R2 to DSX20-LMTS or DSX20-TMTS, 8.
Page 43
DSX2000 follow the procedure described in the instruction manual. Turn the focus handle to raise the stage mount to the upper limit position. Remove four fixing screws and washers (x4 each) using the hex wrench provided with the DSX10-MSTAD, and...
Page 44
DSX2000 The manual stage adapter itself is heavy (approximately 4 kg), so handle it with care when attaching to N O T E avoid dropping it. Align the screw holes (three on the inside) of the manual stage adapter with the mounting holes (3 positions) of the manual stage mount, and tighten the provided fixing screws to secure it in place.
Page 45
DSX2000 Tightening the fixing knobs too firm will cause the plate warp and not level out, so be sure to tighten N O T E them moderately. Detaching Manual Stage (U-SIC4R2) To detach the manual stage, detach it in the reverse order of attaching procedures.
DSX2000 To detach stage plate, perform the procedure described above in reverse order. T I P Attaching wafer holder (BH2-WHR43, U-WHP2) Combine the wafer holder plate U-WHP2 to the stage, and tighten the fixing screws (2 positions). Attach rotating wafer holder BH2-WHR43.
Page 47
DSX2000 turn it slowly and carefully. · There are restrictions on the combination of objective lenses that can be attached to a motorized nosepiece. Use motorized nosepiece in combination with an objective lens that has the same parfocal distance. Check unit combinations for combination restrictions.
Page 48
DSX2000 Turn off the power switch at the bottom of the back of the frame to shut down the system. Loosen the fixing screw with the hexagonal screwdriver provided with the zoom head. Detach nosepiece. Place motorized nosepiece on a soft cloth or the like spread on the desk, and then remove the lens cover...
Page 49
DSX2000 the nosepiece. Screw in the objective lenses in the order of objective mounting index of nosepiece, from the lowest to the highest magnification. Attach the nosepiece with the objective lens attached to the zoom head. Arrange sliding dovetail groove along the zoom head dovetail groove .
Page 50
DSX2000 Loosen the fixing screw with the hexagonal screwdriver provided with the zoom head. Detach nosepiece. 8. Assembly Procedures 8.5 Attaching/Detaching Nosepiece...
DSX2000 8.6 Attaching and Detaching the Cartridge Holder and Cartridges Use the transmitted illumination cartridge holder (DSX20-ICH) in combination with the motorized stage with transmitted illumination (DSX20-TMTS). Installing the Cartridge Holder and Cartridges Pressing too hard or applying large impact may cause the stage glass to break and result in injury. Be N O T E careful when attaching or detaching as the glass may break if dropped.
Page 52
DSX2000 Align the mark on installing illumination cartridge with the mark on illumination cartridge mount. Press it in. When installing a lighting cartridge that has a protrusion on the back, ensure that the lighting N O T E cartridge does not rotate after being pushed in.
· Cables and cords are vulnerable to bend or twist. Do not apply excessive force to them. · Always connect the units specified by Evident to each connector. · Insert the connector by confirming the direction, and be sure to tighten any fixing screws.
Page 54
DSX2000 Cables Connector Description Zoom head rear view [FRAME/CB] Frame back view [HEAD] Zoom head rear view [ZMTR] Zoom head side view [ZMTR] Zoom head camera unit [TRG] Zoom head side view [BNC] AC adapter Zoom head camera unit [ Head side view [USB] Controller PC USB3.1Gen2(10Gbps)
Page 55
DSX2000 Connector Connected Unit Tilting frame DSX20-TF / Upright frame DSX20-UF 8.7.1 Routing of Cables Make sure to route the cables with enough slack so that they do not get strained or pinched when the N O T E zoom head or stage is moved.
Page 56
The following procedure is only required for customers who purchased the zoom head alone. Connect the control box DSX20-CB when you want to use a frame from other than DSX2000 series (DSX20-TF, DSX20-UF) and enable functions of a digital microscope.
Page 57
Always use the power cord provided by Evident. N O T E The power cord should be connected to the grounded 3-core outlet. If the outlet is not grounded, the electric safety performance intended by Evident cannot be assured. 8.7.4 Detaching Cables Disconnect the power cord.
DSX2000 8.8 Attaching the Panel Sheet (Japanese/Chinese) Attaching the Panel Sheet to the Console Remove the protective films from the sheet. Remove backings of all double-side adhesive tapes on the backside of the sheet. Affix the sheet to the Console location 8.
When you need to pack this product, such as to send it to a distant location, you will need a packing box exclusively for this purpose. In this case, always contact an Evident distributor. When transporting the unit again, be sure to attach transportation locks For attaching/detaching instructions, see the chapter on assembly instructions for each unit.
Depending on how the system is used, the system's full potential may not be exhibited although this is not a malfunction. If any problem occurs, see the following and take appropriate measures. If the problem persists, please contact the Evident distributor where you purchased the product. Blackout occurred due to the tripped breaker or other factors...
Page 61
If you cannot solve the problem even after taking the actions listed in the troubleshooting section, please contact Evident distributor. At that time, please tell them the following information as well. · Product name and abbreviation (e.g. Universal zoom head with motorized nosepiece (product name) DSZ20-MZH (abbreviation) ·...
DSX2000 Proper selection of the power supply cord If no power supply cord is provided, please select the proper power supply cord for the equipment by referring to “Specifications” and “Certified Cord” below: Caution : In case you use a non-approved power supply cord for our products, we can no longer warrant the electrical safety of the equipment.
Page 64
DSX2000 Table 2 HAR flexible cord Approval organizations and cordage harmonization marking methods. Alternative marking utilizing Printed or embossed black-red-yellow thread harmonization marking (May (Length of color section in Approval organization be located on jacket or insulation of internal wiring)
Page 65
Life science solutions Industrial solutions Service Center Service Center https://www.olympus- https://www.olympus- lifescience.com/support/service/ ims.com/service-and- support/service-centers/ Official website Official website https://www.olympus- https://www.olympus- lifescience.com ims.com AM5623 01 Issued in November, 2024...
Need help?
Do you have a question about the DSX2000 and is the answer not in the manual?
Questions and answers