Sliding Sleeves; Post-Mounting Check - Endress+Hauser Liquiphant FTL64 Operating Instructions Manual

Point level switch for liquids in high-temperature applications
Hide thumbs Also See for Liquiphant FTL64:
Table of Contents

Advertisement

Mounting
16
1.
 13
Screwing in the device
Aligning the cable entry
1.
3.
 14
Housing with external locking screw and drip loop
The locking screw is not tightened when the device is delivered.
1. Loosen the external locking screw (maximum 1.5 turns).
2. Turn the housing, align the cable entry.
 Avoid moisture in the housing, provide a loop to allow moisture to drain off.
3. Tighten the external locking screw.
5.3

Sliding sleeves

 For more details, see the "Accessories" section.
A
5.4

Post-mounting check

 Is the device undamaged (visual inspection)?
 Does the measuring device meet the measuring point specifications?
2.
2.
4 3.5 Nm
Liquiphant FTL64
A0042423
A0042355
Endress+Hauser