JLG RT2669 Service And Maintenance Manual page 276

Hide thumbs Also See for RT2669:
Table of Contents

Advertisement

SECTION 5 - JLG CONTROL SYSTEM
DTC
Flash
Description
Code
Code
8124
8 1 "Rear Axle Tilt Sensor Has Not Been Cali-
brated"
813
8 1 "Chassis Tilt Sensor Not Calibrated"
814
8 1 "Chassis Tilt Sensor Out Of Range"
815
8 1 "Chassis Tilt Sensor - Disagreement"
818
8 1 "Tilt Sensor Stagnant"
821
8 2 "LSS Front Left Cell #1 Error"
822
8 2 "LSS Front Right Cell #2 Error"
823
8 2 "LSS Rear Left Cell #3 Error"
824
8 2 "LSS Rear Right Cell #4 Error"
825
8 2 "LSS Has Not Been Calibrated"
991
9 9 "LSS Watchdog Reset"
9910
9 9 "Functions Locked Out - Platform Module
Software Version Improper"
99187 9 9 "LSS Internal Error - Driver Failure"
992
9 9 "LSS EEPROM Error"
9924
9 9 "Functions Locked Out - Machine Not Con-
figured"
993
9 9 "LSS Internal Error - Pin Excitation"
994
9 9 "LSS Internal Error - DRDY Missing From A/
D"
998
9 9 "EEPROM Failure - Check All Settings"
5-34
Action
Lift Up and Quik Level Functions Pre-
vented. Drive is prevented if the
Machine is Not Stowed.
Lift Up is Prevented. Drive is pre-
vented if the Machine is Not Stowed.
Lift Up is Prevented. Drive is pre-
vented if the Machine is Not Stowed.
Lift Up is Prevented. Drive is pre-
vented if the Machine is Not Stowed.
Lift Up is Prevented. Drive is pre-
vented if the Machine is Not Stowed.
Machine will behave as if it is over-
loaded.
Machine will behave as if it is over-
loaded.
Machine will behave as if it is over-
loaded.
Machine will behave as if it is over-
loaded.
Machine will behave as if it is over-
loaded.
Machine will behave as if it is over-
loaded.
Machine Functions Prevented in
Platform Mode.
Machine will behave as if it is over-
loaded.
Machine will behave as if it is over-
loaded.
All Machine Functions Prevented.
Machine will behave as if it is over-
loaded.
Machine will behave as if it is over-
loaded.
All Machine Functions Prevented.
Item Check List
• The UGM is detecting that the Rear Axle Tilt Sensor does not
have a Calibrated Value in Memory.
• The UGM is detecting that the Chassis Tilt Sensor does not
have a Calibrated Value in Memory.
• The UGM is detecting that the Chassis Tilt Sensor Value is
reading greater than +/- 30°.
• Check sensor for damage or faulty wiring.
• The Chassis Tilt Sensor has an internal accelerometer dis-
agreement. Tilt Sensor will need replaced.
• The UGM is detecting that the Chassis Tilt Sensor Value is not
changing during Drive.
• Check sensor for damage or faulty wiring.
• UGM is detecting that LSS FL Cell has an Error.
• Check for cable damage or loose connection.
• UGM is detecting that LSS FR Cell has an Error.
• Check for cable damage or loose connection.
• UGM is detecting that LSS RL Cell has an Error.
• Check for cable damage or loose connection.
• UGM is detecting that LSS RR Cell has an Error.
• Check for cable damage or loose connection.
• UGM is detecting that the LSS does not have a Calibrated
Value in Memory.
• The UGM is detecting the LSS Module has an internal fault.
The LSS Module may need replaced.
• UGM is detecting that there is a Software Version error
between the UGM and Platform Module.
• Check that both modules have the latest SW version pro-
grammed to them.
• The UGM is detecting the LSS Module has an internal fault.
The LSS Module may need replaced.
• The UGM is detecting the LSS Module has an internal fault.
The LSS Module may need replaced.
• UGM is detecting that under MACHINE SETUP in the Analyzer
there is not a machine model selected.
• The UGM is detecting the LSS Module has an internal fault.
The LSS Module may need replaced.
• The UGM is detecting the LSS Module has an internal fault.
The LSS Module may need replaced.
• UGM is detecting an internal EEPROM error.
31215923