INSTALLATION

• Choose the desired location for the
Moisture Drain Kit Bottle and verify
that the existing compressor oil drain
hose adequately reaches and will
attach to the Brass Barbed Fitting
(FIG. 4).
• Using holes in the Mount, mark the
holes to be drilled (FIG. 5).
• Drill the two 1/4" holes into the frame.
• Using the two M6 Hex Drive Round
Head Screw with Nut, attach the
Moisture Drain Kit assembly to the
frame (FIG. 6).
• Slip the existing oil drain hose over the
Brass Barbed Fitting on the Moisture
Drain Kit Lid, attaching it securely
(FIG. 6).
• Apply included Warning Label onto the
side of the Oil Tank (FIG. 7).
• Once kit is installed user can:
- Notch cover flange to offer
clearance for drain hose.
- Remove drain hose after each use.
- Operate unit WITHOUT cover
installed- which is completely
acceptable and expedites
moisture draining operations.
To order parts and supplies: 800.343.9353 >> eastwood.com